Key Specifications
GTIN: 4055626444864
Orderkey: 2910344
(General): ≤ 0.275 kV (at 3 kA)
Packing unit: 1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4055626444864
Orderkey 2910344
(General) ≤ 0.275 kV (at 3 kA)
Packing unit 1 pc
Country of origin US (United States)
(Connection data) (DC+) - G
Custom tariff number 85363030
(Ambient conditions) PBT
(Protective circuit) 1 A DC
(UL connection data) EN 61643-11 2012
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) jet black RAL 9005
Response time tA (General) ≤ 25 ns
SPD Type (Connection data) 4CA
Depth (Key Commercial Data) 65.5 mm
Width (Key Commercial Data) 35.6 mm
EN type (Ambient conditions) T2
Height (Key Commercial Data) 96.8 mm
Nominal voltage UN (General) 60 V DC ±10 %
(Indicator/remote signaling) 4.5 Nm (25 mm² ... 35 mm²)
Residual current IPE (General) ≤ 0.45 mA
Shock (operation) (Dimensions) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 80 A
Residual voltage Ures (General) ≤ 0.55 kV (at In)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Nominal voltage (Connection data) 60 V DC
Screw thread (Protective circuit) M2
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Mode of protection (Connection data) (DC+) - (DC-)
Weight per Piece (excluding packing) 190.000 g
Housing material (Ambient conditions) PA 6.6
Operating current (UL specifications) 1 A AC
Operating voltage (UL specifications) 125 V AC
Stripping length (Protective circuit) 7 mm
Tightening torque (UL specifications) 2 lbf-in. ... 4 lbf-in.
Connection method (Protective circuit) Screw connection
Horizontal pitch (Key Commercial Data) 2 Div.
Operating current (Protective circuit) 5 mA AC ... 1.5 A AC
Operating voltage (Protective circuit) 5 V AC ... 250 V AC
Tightening torque (Protective circuit) 0.25 Nm
Maximum continuous voltage UC (General) 100 V DC
Mode of protection (Ambient conditions) (DC+) - (DC-)
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 2
Screw thread (Indicator/remote signaling) M5
Standards/regulations (UL connection data) IEC 61643-11 2011
Power distribution system (Connection data) DC
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) DC
IEC test classification (Ambient conditions) II
Short-circuit current rating ISCCR (General) 5 kA
Max. backup fuse with branch wiring (General) 125 A (gG)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Screw connection
Nominal discharge current In (Connection data) 20 kA
Tightening torque (Indicator/remote signaling) 4.5 Nm (1,5 mm² ... 16 mm²)
Conductor cross section AWG (UL specifications) 30 ... 14
Conductor cross section AWG (Protective circuit) 28 ... 16
Nominal discharge current In(8/20) µs (General) 15 kA
Maximum Surge Current per Phase (Connection data) 40 kA
Tightening torque (UL indicator/remote signaling) 30 lbf-in.
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Voltage protection level Up(DC+) - (DC-) (General) ≤ 0.55 kV
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Voltage protection level Up(DC+/DC-) - PE (General) ≤ 0.55 kV
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General) 80 A (gG)
Conductor cross section AWG (Indicator/remote signaling) 15 ... 2
Conductor cross section solid (Indicator/remote signaling) 1.5 mm² ... 35 mm²
Conductor cross section AWG (UL indicator/remote signaling) 10 ... 2
Flammability rating according to UL 94 (Ambient conditions) V-0
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 25 mm²

Product Description

2-channel surge protection device with remote indication contact, for 48 V DC, 2 wires plus ground.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty