Service time: Monday to Friday 9:00-18:00
VAL-US-240/40/2+0-FM - VAL-US-240/40/2+0-FM 2910364 PHOENIX CONTACT Type 2 surge protection device
In Stock Hot Product

VAL-US-240/40/2+0-FM

VAL-US-240/40/2+0-FM 2910364 PHOENIX CONTACT Type 2 surge protection device

$0.00 USD
4412 in stock
Key Specifications
: T2
Note: 2011
Type: DIN rail module, two-section, divisible
Color: black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
T2
Note 2011
Type DIN rail module, two-section, divisible
Color black (RAL 9005)
Depth 65.7 mm (incl. DIN rail 7.5 mm)
Width 35.6 mm
Height 96.8 mm
EN type T2
UL type type 1
Altitude ≤ 2000 m (amsl)
SPD Type 1
Product type Surge protection for NEMA power supply units
Screw thread M5
Mounting type DIN rail: 35 mm
Material group I
Product family VALVETRAB US
Connection name Remote fault indicator contact
Nominal voltage 240/480 V AC (Split phase)
Article revision 04
Horizontal pitch 2 Div.
Housing material PA 6.6
Pollution degree 2
Response time tA ≤ 25 ns
Stripping length 16 mm
Connection method Screw connection
Nominal frequency 50/60 Hz
Operating current 5 mA AC ... 750 mA AC
Operating voltage 5 V AC ... 250 V AC
Shock (operation) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque 3 Nm (1.5 mm² ... 16 mm²)
Mode of protection L-PEN
Nominal voltage UN 240/480 V AC (TN-C)
Switching function Changeover contact
TOV behavior at UT 415 V AC (5 s / withstand mode)
Dimensional drawing
Direction of action 2L-GND
Insulating material PA 6.6/PBT
Number of positions 2
AC operating current 1 A AC
Degree of protection IP20 (only when all terminal points are used)
Nominal frequency fN 50 Hz (60 Hz)
Overvoltage category III
CTI value of material 600
Residual voltage Ures ≤ 1.8 kV (at In)
Standards/regulations EN 60664-1 / EN 61643-11
Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
IEC power supply system TN-C
IEC test classification II
Standards/specifications IEC 61643-11
Power distribution system Split phase
Conductor cross section AWG 15 ... 2
Voltage protection level Up ≤ 1.8 kV
Nominal discharge current In 20 kA
Residual voltage Ures(L-PEN) ≤ 1.8 kV (at In)
Conductor cross section rigid 1.5 mm² ... 35 mm²
Maximum continuous voltage UC 385 V AC
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -40 °C ... 80 °C
Maximum Surge Current per Phase 40 kA
Conductor cross section flexible 1.5 mm² ... 25 mm²
Permissible humidity (operation) 5 % ... 95 %
Short-circuit current rating ISCCR 25 kA
Max. backup fuse with branch wiring 125 A (gG)
Short-circuit current rating (SCCR) 200 kA
Voltage protection rating VPR (L-G) 1500 V
Voltage protection rating VPR (L-L) 2500 V
Flammability rating according to UL 94 V-0
Nominal discharge current In(8/20) µs 20 kA
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs 40 kA
Maximum continuous operating voltage MCOV (L-G) 385 V AC
Maximum continuous operating voltage MCOV (L-L) 750 V AC

Product Description

2-channel surge protection device with remote indication contact, for 240/480 V AC (split phase configuration), 3 wires.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top