Key Specifications
GTIN: 4055626444956
Note: Made to Order (non-returnable)
Orderkey: 2910355
(General): 240 V AC (120 min / safe failure mode)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4055626444956
Note Made to Order (non-returnable)
Orderkey 2910355
(General) 240 V AC (120 min / safe failure mode)
Packing unit 1 pc
Country of origin US (United States)
(Connection data) L-G
Custom tariff number 85363030
(Ambient conditions) PBT
(Protective circuit) 1 A DC
(UL connection data) EN 61643-11 2012
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) jet black RAL 9005
Response time tA (General) ≤ 25 ns
SPD Type (Connection data) 1
Depth (Key Commercial Data) 77.5 mm
Width (Key Commercial Data) 17.8 mm
EN type (Ambient conditions) T1 / T2
Height (Key Commercial Data) 96.8 mm
Nominal voltage UN (General) 120 V AC (TN-C)
TOV behavior at UT (General) 208 V AC (5 s / withstand mode)
(Indicator/remote signaling) 4.5 Nm (25 mm² ... 35 mm²)
Nom. voltage (Connection data) 120 V AC (Single-phase)
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual current IPE (General) ≤ 0.8 mA
Shock (operation) (Dimensions) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 80 A
Residual voltage Ures (General) ≤ 0.8 kV (at In)
Degree of protection (Dimensions) IP20 (only when all terminal points are used)
Screw thread (Protective circuit) M2
Mounting type (Ambient conditions) DIN rail: 35 mm
Vibration (operation) (Dimensions) 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Nominal frequency (Connection data) 50/60 Hz
Mode of protection (Connection data) L-N
Weight per Piece (excluding packing) 150.000 g
Housing material (Ambient conditions) PA 6.6
Operating current (UL specifications) 1 A AC
Operating voltage (UL specifications) 125 V AC
Stripping length (Protective circuit) 7 mm
Tightening torque (UL specifications) 2 lbf-in. ... 4 lbf-in.
Voltage protection level Up (General) ≤ 0.8 kV
Connection method (Protective circuit) Screw connection
Horizontal pitch (Key Commercial Data) 1 Div.
Operating current (Protective circuit) 5 mA AC ... 1.5 A AC
Operating voltage (Protective circuit) 5 V AC ... 250 V AC
Tightening torque (Protective circuit) 0.25 Nm
Mode of protection (Ambient conditions) L-PEN
Switching function (Protective circuit) PDT contact
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 1
Screw thread (Indicator/remote signaling) M5
Standards/regulations (UL connection data) IEC 61643-11 2011
Power distribution system (Connection data) Single phase
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) TN-C
IEC test classification (Ambient conditions) I / II
Short-circuit current rating ISCCR (General) 25 kA
Max. backup fuse with branch wiring (General) 160 A (gG)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Stripping length (Indicator/remote signaling) 16 mm
Connection method (Indicator/remote signaling) Screw connection
Nominal discharge current In (Connection data) 20 kA
Tightening torque (Indicator/remote signaling) 4.5 Nm (1,5 mm² ... 16 mm²)
Conductor cross section AWG (UL specifications) 30 ... 14
Voltage protection rating VPR (Connection data) 700 V
Conductor cross section AWG (Protective circuit) 28 ... 16
Nominal discharge current In(8/20) µs (General) 20 kA
Maximum Surge Current per Phase (Connection data) 65 kA
Tightening torque (UL indicator/remote signaling) 30 lbf-in.
Conductor cross section solid (Protective circuit) 0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (General) 65 kA
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General) 12.5 kA
Conductor cross section flexible (Protective circuit) 0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General) 80 A (gG)
Short-circuit current rating (SCCR) (Connection data) 200 kA
Conductor cross section AWG (Indicator/remote signaling) 15 ... 2
Maximum continuous operating voltage UC(L-PEN) (General) 175 V AC
Conductor cross section solid (Indicator/remote signaling) 1.5 mm² ... 35 mm²
Conductor cross section AWG (UL indicator/remote signaling) 10 ... 2
Flammability rating according to UL 94 (Ambient conditions) V-0
Maximum continuous operating voltage MCOV (Connection data) 175 V AC
Conductor cross section flexible (Indicator/remote signaling) 1.5 mm² ... 25 mm²

Product Description