Service time: Monday to Friday 9:00-18:00
VAL-SEC-T2-3C-440-FM - VAL-SEC-T2-3C-440-FM 2909968 PHOENIX CONTACT Type 2 surge arrester
In Stock Hot Product

VAL-SEC-T2-3C-440-FM

VAL-SEC-T2-3C-440-FM 2909968 PHOENIX CONTACT Type 2 surge arrester

$0.00 USD
3242 in stock
Key Specifications
: T2
Note: Usable in all low-voltage systems between L-N or L-PEN.Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation. (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. RE= RAaccordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a)
Type: DIN rail module, two-section, divisible
Depth: 74.5 mm (incl. DIN rail 7.5 mm)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
T2
Note Usable in all low-voltage systems between L-N or L-PEN.Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation. (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. RE= RAaccordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a)
Type DIN rail module, two-section, divisible
Depth 74.5 mm (incl. DIN rail 7.5 mm)
Width 37.3 mm
Height 97.9 mm
EN type T2
Altitude ≤ 2000 m (amsl)
Product type Surge arrester
Screw thread M5
Mounting type DIN rail: 35 mm
Material group I
Product family SEC Family
Connection name Remote fault indicator contact
Article revision 03
Horizontal pitch 2 Div.
Housing material PA 6.6-FR 20 % GF
Pollution degree 2
Response time tA ≤ 25 ns
Stripping length 16 mm
Connection method Screw connection
Operating current 5 mA AC ... 1 A AC
Operating voltage 5 V AC ... 250 V AC
Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque 4.5 Nm
Mode of protection L-PEN
Nominal voltage UN 400/690 V AC (TN-C)
Switching function Changeover contact
TOV behavior at UT 581 V AC (5 s / withstand mode)
Dimensional drawing
Direction of action 3L-N/PE
Insulating material PA6.6-FR 20% GF
Number of positions 3
Color (Base element) gray (RAL 7042)
Degree of protection IP20
Nominal frequency fN 50 Hz (60 Hz)
Overvoltage category III
CTI value of material 600
Rated load current IL 40 A (Biconnect M4 fork-type cable lug 6​ mm²)
Residual voltage Ures ≤ 1.9 kV (at In)
Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Color (Male connector) light gray (RAL 7035)
IEC power supply system TN-C
IEC test classification II
Standards/specifications IEC 61643-11
Conductor cross section AWG 12 ... 4
Voltage protection level Up ≤ 1.9 kV
Standby power consumption PC ≤ 540 mVA
Conductor cross section rigid 2.5 mm² ... 25 mm²
Maximum continuous voltage UC 440 V AC
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -40 °C ... 80 °C
Conductor cross section flexible 2.5 mm² ... 16 mm²
Permissible humidity (operation) 5 % ... 95 %
Short-circuit current rating ISCCR 25 kA (for a backup fuse of up to 315 A gG)
Max. backup fuse with branch wiring 315 A (gG)
Flammability rating according to UL 94 V-0
Nominal discharge current In(8/20) µs 20 kA
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs 40 kA
Max. backup fuse with V-type through wiring 40 A (gG / Biconnect M4 fork-type cable lug, 6​ mm²)

Product Description

Plug-in surge arrester according to type 2/class II, for three-phase power supply networks with PE and N routing combined in one conductor (4-conductor system: L1, L2, L3, PEN), with remote indication
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top