Service time: Monday to Friday 9:00-18:00
VAL-MS-T1/T2 335/12.5/4+0 - VAL-MS-T1/T2 335/12.5/4+0 2800645 PHOENIX CONTACT Lightning/surge arrester type 1/2
In Stock Hot Product

VAL-MS-T1/T2 335/12.5/4+0

VAL-MS-T1/T2 335/12.5/4+0 2800645 PHOENIX CONTACT Lightning/surge arrester type 1/2

$0.00 USD
4595 in stock
Key Specifications
: T1 / T2
Note: 2011
Type: DIN rail module, two-section, divisible
Color: black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
T1 / T2
Note 2011
Type DIN rail module, two-section, divisible
Color black (RAL 9005)
Depth 77.5 mm (incl. DIN rail 7.5 mm)
Width 71.2 mm
Height 89.8 mm
EN type T1 / T2
Altitude ≤ 2000 m (amsl)
SPD Type 4CA
Product type Arrester combination
Screw thread M5
Mounting type DIN rail: 35 mm
Material group I
Product family VALVETRAB MS
Nominal voltage 415/240 V AC
Open side panel No
Article revision 09
Horizontal pitch 4 Div.
Housing material PA 6.6
Pollution degree 2
Response time tA ≤ 25 ns
Stripping length 16 mm
Connection method Screw connection
Nominal frequency 50/60 Hz
Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque 3 Nm (1.5 mm² ... 16 mm²)
Mode of protection L-PE
Nominal voltage UN 240/415 V AC (TN-S)
TOV behavior at UT 415 V AC (5 s / withstand mode)
Dimensional drawing
Direction of action 3L-N/PE
Insulating material PA 6.6/PBT
Number of positions 4
Degree of protection IP20 (only when all terminal points are used)
Nominal frequency fN 50 Hz (60 Hz)
Overvoltage category III
Residual current IPE ≤ 3.2 mA
CTI value of material 600
Rated load current IL 80 A
Residual voltage Ures ≤ 1.2 kV (at In)
Vibration (operation) 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
IEC power supply system TN-S
IEC test classification I / II
Standards/specifications IEC 61643-11
Power distribution system Wye
Conductor cross section AWG 15 ... 2
Voltage protection level Up ≤ 1.2 kV
Standby power consumption PC ≤ 1080 mVA
Conductor cross section rigid 1.5 mm² ... 35 mm²
Maximum continuous voltage UC 335 V AC
Surge protection fault message optical
Ambient temperature (operation) -40 °C ... 80 °C
Conductor cross section flexible 1.5 mm² ... 25 mm²
Permissible humidity (operation) 5 % ... 95 %
Nominal discharge current In(L-G) 20 kA
Nominal discharge current In(L-L) 20 kA
Nominal discharge current In(L-N) 20 kA
Nominal discharge current In(N-G) 20 kA
Short-circuit current rating ISCCR 25 kA
Max. backup fuse with branch wiring 160 A (gG)
Measured limiting voltage MLV (L-G) 2630 V
Measured limiting voltage MLV (L-L) 3650 V
Measured limiting voltage MLV (L-N) 3650 V
Measured limiting voltage MLV (N-G) 2630 V
Flammability rating according to UL 94 V-0
Nominal discharge current In(8/20) µs 12.5 kA
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs 50 kA
Total discharge current Itotal(8/20) µs 200 kA
Max. backup fuse with V-type through wiring 80 A (gG - 16 mm²)
Total discharge current Itotal(10/350) µs 50 kA
Impulse discharge current (10/350) µs, charge 6.5 As
Maximum continuous operating voltage MCOV (L-G) 335 V AC
Maximum continuous operating voltage MCOV (L-L) 670 V AC
Maximum continuous operating voltage MCOV (L-N) 670 V AC
Maximum continuous operating voltage MCOV (N-G) 335 V AC
Impulse discharge current (10/350) µs, peak value limp 12.5 kA
Impulse discharge current (10/350) µs, specific energy 39 kJ/Ω

Product Description

Universal pluggable lightning current / surge arrester equipped with varistors for three-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE).
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top