Service time: Monday to Friday 9:00-18:00
VAL-MS 385/65/3+0-FM - VAL-MS 385/65/3+0-FM 2921006 PHOENIX CONTACT Type 2 surge arrester for 4-wire power supply systems (L1, L2, ..
In Stock Hot Product

VAL-MS 385/65/3+0-FM

VAL-MS 385/65/3+0-FM 2921006 PHOENIX CONTACT Type 2 surge arrester for 4-wire power supply systems (L1, L2, ..

$0.00 USD
4700 in stock
Key Specifications
: IP20 (only when all terminal points are used)
Type: DIN rail module, two-section, divisible
Color: black
Depth: 77.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
IP20 (only when all terminal points are used)
Type DIN rail module, two-section, divisible
Color black
Depth 77.5 mm
Width 53.4 mm
Height 99 mm
EN type T2
Altitude ≤ 2000 m (amsl (above mean sea level))
Screw thread M5
Mounting type DIN rail: 35 mm
UT(TOV-proof) 480 V AC (5 s / L-N)
Connection name Remote fault indicator contact
Horizontal pitch 3 Div.
Housing material PA 6.6
Stripping length 16 mm
Connection method Screw connection
Shock (operation) 30g
Tightening torque 4.5 Nm
Connection type IN Biconnect screw terminal block
Nominal voltage UN 240/415 V AC (TN-C)
Switching function PDT contact
Connection type OUT Biconnect screw terminal block
Direction of action 3L-PEN
Degree of protection IP20
Nominal frequency fN 50 Hz (60 Hz)
Residual current IPE ≤ 1800 µA
Rated load current IL 80 A
Standards/regulations IEC 61643-11 2011
Vibration (operation) 7.5g
Response time tA(L-PE) ≤ 25 ns
IEC power supply system TN-C
IEC test classification II
Residual voltage (L-PEN) ≤ 1.3 kV
Conductor cross section AWG 15 ... 2
Max. operating current Imax 1.5 A AC (250 V AC)
Standby power consumption PC ≤ 690 mVA
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -40 °C ... 80 °C
Conductor cross section AWG max. 2
Conductor cross section AWG min. 15
Permissible humidity (operation) 5 % ... 95 %
Maximum operating voltage Umax.AC 250 V AC
Conductor cross section solid max. 35 mm²
Conductor cross section solid min. 1.5 mm²
Short-circuit current rating ISCCR 25 kA
Voltage protection level Up(L-PEN) ≤ 1.8 kV
Max. backup fuse with branch wiring 250 A AC (gG)
Conductor cross section flexible max. 25 mm²
Conductor cross section flexible min. 1.5 mm²
Flammability rating according to UL 94 V-0
Ambient temperature (storage/transport) -40 °C ... 80 °C
Max. backup fuse with V-type through wiring 80 A AC (gG - 16 mm²)
Nominal dischargecurrent In(8/20) µs (L-PEN) 30 kA
Maximum continuous operating voltage UC(L-PEN) 385 V AC
Standards for cearances and creepage distances EN 60664-1
Max. discharge current Imax(8/20) µs maximum (L-PEN) 65 kA
Short-circuit resistance IPwith max. backup fuse (effective) 25 kA

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top