Service time: Monday to Friday 9:00-18:00
VAL-MS 320 RW ST - VAL-MS 320 RW ST 1050283 PHOENIX CONTACT Type 2 surge protection plug
In Stock Hot Product

VAL-MS 320 RW ST

VAL-MS 320 RW ST 1050283 PHOENIX CONTACT Type 2 surge protection plug

$0.00 USD
3135 in stock
Key Specifications
GTIN: 4055626666112
Note: Made to Order (non-returnable)
Orderkey: 1050283
(General): 440 V AC (120 min / safe failure mode)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4055626666112
Note Made to Order (non-returnable)
Orderkey 1050283
(General) 440 V AC (120 min / safe failure mode)
Packing unit 10 pc
Country of origin DE (Germany)
(Connection data) EN 61643-11 2012
Custom tariff number 85363090
(Ambient conditions) L-PEN
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Minimum order quantity 10 pc
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) jet black RAL 9005
Response time tA (General) ≤ 25 ns
Depth (Key Commercial Data) 55.3 mm
Width (Key Commercial Data) 17.5 mm
EN type (Ambient conditions) T2
Height (Key Commercial Data) 52.4 mm
Nominal voltage UN (General) 240/415 V AC (TN)
TOV behavior at UT (General) 415 V AC (5 s / withstand mode)
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual current IPE (General) ≤ 0.45 mA
Shock (operation) (Dimensions) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Residual voltage Ures (General) ≤ 1.5 kV (at In)
Degree of protection (Dimensions) IP20
Mounting type (Ambient conditions) on base element
Vibration (operation) (Dimensions) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Weight per Piece (excluding packing) 63.200 g
Housing material (Ambient conditions) PA 6.6
Voltage protection level Up (General) ≤ 1.5 kV
Connection method (Protective circuit) pluggable
Horizontal pitch (Key Commercial Data) 1 Div.
Standby power consumption PC (General) ≤ 150 mVA
Maximum continuous voltage UC (General) 335 V AC
Mode of protection (Ambient conditions) L-N
Standards/regulations (Connection data) IEC 61643-11 2011
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 1
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC test classification (Ambient conditions) II
Short-circuit current rating ISCCR (General) 25 kA
Max. backup fuse with branch wiring (General) 125 A (gG)
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Nominal discharge current In(8/20) µs (General) 20 kA
Maximum discharge current Imax(8/20) µs (General) 40 kA
Surge protection fault message (Ambient conditions) optical
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Impulse discharge current (10/350) µs, charge (General) 3.5 As
Flammability rating according to UL 94 (Ambient conditions) V-0
Impulse discharge current (10/350) µs, peak value limp (General) 7 kA
Impulse discharge current (10/350) µs, specific energy (General) 12.25 kJ/Ω

Product Description

Plug-in type 2 surge protection with high-power varistor for VAL-MS base element, with thermal control, optical fault indication. Version: 320 V AC with increased lightning current shunt capability.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top