VAL-MS 1000DC-PV/2+V-FM - VAL-MS 1000DC-PV/2+V-FM 2800627 PHOENIX CONTACT Surge arrester for 2-pos. isolated 1000 V DC voltage systems..
In Stock Hot Product

VAL-MS 1000DC-PV/2+V-FM

VAL-MS 1000DC-PV/2+V-FM 2800627 PHOENIX CONTACT Surge arrester for 2-pos. isolated 1000 V DC voltage systems..

$0.00 USD
4066 in stock
Key Specifications
: PV T2
Note: The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Type: DIN rail module, two-section, divisible
Color: jet black RAL 9005
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
PV T2
Note The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Type DIN rail module, two-section, divisible
Color jet black RAL 9005
Depth 65.5 mm
Width 53.4 mm
Height 99 mm
Altitude ≤ 2000 m (amsl (above mean sea level))
SPD Type 4 (for Type 2 photovoltaic applications)
SPD design Voltage-limiting type
Nom. voltage 970 V AC
Screw thread M2
Accessibility Accessible
Mounting type DIN rail: 35 mm
Connection name Remote fault indicator contact
Number of ports One
Horizontal pitch 3 Div.
Housing material PA 6.6-FR
Pollution degree 2
Stripping length 7 mm
Connection method Screw connection
Operating current 5 mA AC ... 1.5 A AC
Operating voltage 5 V AC ... 250 V AC
Shock (operation) 60g (Half sine/11 ms/3x XYZ)
Tightening torque 0.25 Nm
Mode of protection (L+) - (L-)
Switching function PDT contact
Degree of protection IP20 (only when all terminal points are used)
Residual current IPE ≤ 20 µA DC
SPD failure behavior OCM (Open-circuit mode)
Installation location Inside
Rated load current IL 80 A
Vibration (operation) 7.5g (5-500 Hz/2.5 h/XYZ)
IEC test classification PV T2
Connection configuration Y configuration
Response time tA(L-) -PE ≤ 25 ns
Standards/specifications EN 50539-11 2013
Power distribution system 1
Response time tA(L+) - PE ≤ 25 ns
Insulation resistance Riso > 5 GΩ (at 500 V DC)
Conductor cross section AWG 28 ... 16
Open circuit voltage UOCSTC ≤ 970 V DC
Response time tA(L+) - (L-) ≤ 25 ns
Standby power consumption PC ≤ 25 mVA
Residual voltage Ures(L+) - PE ≤ 3.7 kV (at In)
Residual voltage Ures(L-) - PE ≤ 3.7 kV (at In)
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -40 °C ... 80 °C
Permissible humidity (operation) 5 % ... 95 %
Residual voltage Ures(L+) - (L-) ≤ 3.7 kV (at In)
Continuous operating current ICPV < 20 µA
Conductor cross section solid max. 1.5 mm²
Conductor cross section solid min. 0.14 mm²
Short-circuit current rating ISCPV 1000 A
Nominal discharge current (8/20) µs 15 kA
Nominal discharge current In(L+) - G 10 kA
Nominal discharge current In(L-) - G 10 kA
Voltage protection level Up(L+) - PE ≤ 3.7 kV
Voltage protection level Up(L-) - PE ≤ 3.7 kV
Conductor cross section flexible max. 1.5 mm²
Conductor cross section flexible min. 0.14 mm²
Voltage protection rating VPR (L-) -G 2.5 kV
Flammability rating according to UL 94 V-0
Voltage protection level Up(L+) - (L-) ≤ 3.7 kV
Voltage protection rating VPR (L+) - G 2.5 kV
Ambient temperature (storage/transport) -40 °C ... 80 °C
Nominal discharge current In(L+) - (L-) 10 kA
Distance between live and grounded parts 8 mm
Maximum discharge current Imax(8/20) µs 40 kA
Maximum continuous operating voltage UCPV 1170 V DC
Total discharge current ITotal(8/20) µs 40 kA
Voltage protection rating VPR (L+) - (L-) 2.5 kV
Installation location of the disconnect device Internal
Nominal discharge current In(8/20) µs (L+) - PE 15 kA
Nominal discharge current In(8/20) µs (L-) - PE 15 kA
Maximum continuous operating voltage MCOV (L+) - G 1170 V DC
Maximum continuous operating voltage MCOV (L-) - G 1170 V DC
Maximum discharge current Imax(8/20) µs (L+) - PE 40 kA
Maximum discharge current Imax(8/20) µs (L-) - PE 40 kA
Nominal discharge current In(8/20) µs (L+) - (L-) 15 kA
Maximum discharge current Imax(8/20) µs (L+) - (L-) 40 kA
Maximum continuous operating voltage MCOV (L+) - (L-) 1170 V DC

Product Description

Surge protection device for isolated and grounded 2-pole photovoltaic 1000V DC direct current systems, for rail mounting, 3-pole base element with remote indication contact, three plug-in protection e
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top