Key Specifications
: 5 V DC ... 30.8 V DC
Fuse: M1 (normal blow)
Note: No. 235
Type: DIN rail module, one-piece
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
5 V DC ... 30.8 V DC
Fuse M1 (normal blow)
Note No. 235
Type DIN rail module, one-piece
Color gray (RAL 7042)
Depth 89.5 mm
Width 12.3 mm
Height 85.5 mm
Altitude 2000 m (acc. to EN 60934)
Fuse type Automatic device
Potentials 1
Product type Thermomagnetic device circuit breakers
Screw thread M4
Mounting type DIN rail: 35 mm
Rated voltage 240 V AC (50/60 Hz)
Number of rows 1
Product family UT 6-TMC
Tripping level Trip-free mechanism (positive)
Connection name Auxiliary contact
No. of channels 1
Nominal current 2 A
Nominal voltage 240 V AC
Open side panel No
Tripping method TM (thermomagnetic)
Article revision 07
Rated current IN 2 A
Stripping length 12 mm
Connection method Screw connection
Cross section AWG 24 ... 8 (converted acc. to IEC)
Device resistance 330 mΩ
Operating voltage 50 V AC ... 264 V AC (48 - 62 Hz)
Power dissipation ≤ 1.32 VA
Tightening torque 1.5 ... 1.8 Nm
Type of actuation S type
Degree of pollution 2
Dielectric strength 2000 V
Insulating material PA66
Number of positions 1
Rated surge voltage 2.8 kV
Degree of protection IP40 (Actuation area)
Overvoltage category II
Required backup fuse 16 A
Temperature derating 1.54 A DC (at -30 °C)
Nominal cross section 6.00 mm²
Number of connections 2
Switching cycles, max. 6000 (at 1 x In)
Rated cross section AWG 8
Standards/specifications EN 60934
Insulation resistance Riso > 100 MΩ (main contact)
Conductor cross section AWG 24 ... 8
Rated insulation voltage Ui 440 V AC
Conductor cross section rigid 0.2 mm² ... 10 mm²
Ambient temperature (operation) -30 °C ... 60 °C
Conductor cross section flexible 0.2 mm² ... 10 mm²
Flammability rating according to UL 94 V-0
Conductor cross section, flexible [AWG] 24 ... 8 (converted acc. to IEC)
Rated short-circuit switching capacity Icn 200 A (240 V AC)
2 conductors with same cross section, solid 0.2 mm² ... 2.5 mm²
2 conductors with same cross section, flexible 0.2 mm² ... 2.5 mm²
Maximum power dissipation for nominal condition ≤ 1.32 VA
Flexible conductor cross section (ferrule with plastic sleeve) 0.25 mm² ... 6 mm²
Conductor cross-section flexible (ferrule without plastic sleeve) 0.25 mm² ... 6 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 6 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 6 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 4 mm²