Service time: Monday to Friday 9:00-18:00
USF4CF55 - USF4CF55 SF4C-F55 PANASONIC Ultra-slim Safety Light Curtain Typ4 (PLe SIL3), Finger Protection, protective h..
In Stock Hot Product

USF4CF55

USF4CF55 SF4C-F55 PANASONIC Ultra-slim Safety Light Curtain Typ4 (PLe SIL3), Finger Protection, protective h..

$0.00 USD
3500 in stock
Key Specifications
Item: Specifications
PFHD: 4.50 × 10-9
Cable: 0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong
MTTFD: 100 years or more
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Item Specifications
PFHD 4.50 × 10-9
Cable 0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong
MTTFD 100 years or more
Details Min. sensing object ø14 mmø0.551 intype (10 mm0.394 inbeam pitch) [Cable type]
Product Ultra-slim Safety Light Curtain [Type 4 PLe SIL3]
Material Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloy
Beam pitch 10 mm0.394 in
Accessories MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR14 (Test rod): 1 No.
Part Number SF4C-F55
Product name Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C
ELCA function Incorporated (reducing mutual interference automatically)
Power voltage 24 V DC +10-15 % Ripple P-P 10 % or less
Response time OFF response: 9 ms or lessON response: 90 ms or less
Product Number SF4C-F55
Cable extension Extension up to 40.5 m132.874 ftis possible for both emitter and receiver, with 0.2 mm2or more cable.(Note) When the muting lamp is used, the cable can be extended within 30.5 m100.066 ft(for emitter / receiver).
Muting function Incorporated
Operating range 0.1 to 3 m0.328 to 9.843 ft(Note) The operating range is the possible setting distance between the emitter and the receiver.
Emitting element Infrared LED (Peak emission wavelength: 855 nm0.034 mil)
Pollution degree 3
Override function Incorporated
Protective height 560 mm22.047 in
Interlock function Incorporated [Manual reset / Automatic reset (Note)](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Operating altitude 2,000 m6,561 68 ftor less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.)
Optional functions Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting(Note) In case of using optional function, the handy-controller SFC-HC is required.
Ambient illuminance Incandescent light: 5,000 lx or less at the light-receiving face
Min. sensing object ø14 mmø0.551 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed.
No. of beam channels 55
Safety input function Incorporated (safety contact)
Effective aperture angle plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)]
Applicable standards:Japan JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3(SIL3)
Applicable standards:Europe EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
Test / reset input function Incorporated
Control outputs (OSSD 1, OSSD 2) PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 200 mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less[When selecting NPN output]- Max. sink current: 200 mA- Applied voltage: same as supply voltage (between the control output and 0 V)- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less
Applicable standards:North America ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark.
External device monitoring function Incorporated
Auxiliary output (Non-safety output) PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and +V)- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m32.808 ftlength cable)[When selecting NPN output]- Max. sink current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m32.808 ftlength cable)
Applicable regulations and certifications CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification
Environmental resistance:Ambient humidity 30 to 85 % RH, Storage: 30 to 85 % RH
Environmental resistance:Shock resistance 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each
Net weight (Total of emitter and receiver) 930 g approx.
Applicable standards:International standard IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3)
Environmental resistance:Ambient temperature -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉
Environmental resistance:Degree of protection IP67 / IP65 (IEC)
Environmental resistance:Vibration resistance 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each
Environmental resistance:Insulation resistance 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Control outputs (OSSD 1, OSSD 2):Operation mode ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed.
Control outputs(OSSD1, OSSD2):Protection circuit Incorporated
Environmental resistance:Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Auxiliary output (Non-safety output):Operation mode OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller).
Auxiliary output (Non-safety output):Protection circuit Incorporated
Current consumption:Large multipurpose indicator lights up Emitter: 120 mA or lessReceiver: 125 mA or less
Current consumption:Large multipurpose indicator lights off Emitter: 85 mA or lessReceiver: 95 mA or less

Product Description

SF4C safety barrier category 4, Ple, SIL3, 0.1 to 3m, "finger" protection 10 mm between beams, 13mm thick, protected height 560mm, operating range 0.1 to 3m, cable 5m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top