Service time: Monday to Friday 9:00-18:00
USF2CH24P - USF2CH24P SF2C-H24-P PANASONIC Ultra-slim Safety Light Curtain Typ2 (PLc SIL1), Hand Protection, protective ..
In Stock Hot Product

USF2CH24P

USF2CH24P SF2C-H24-P PANASONIC Ultra-slim Safety Light Curtain Typ2 (PLc SIL1), Hand Protection, protective ..

$0.00 USD
4713 in stock
Key Specifications
Item: Specifications
PFHD: 3.85 × 10-9(Note) Probability of dangerous failure per hour.
Cable: 0.16 mm25-core heat-resistant PVC cable, 3 m 9.842 ft long
MTTFD: 100 years or more(Note) Mean time to dangerous failure.
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Item Specifications
PFHD 3.85 × 10-9(Note) Probability of dangerous failure per hour.
Cable 0.16 mm25-core heat-resistant PVC cable, 3 m 9.842 ft long
MTTFD 100 years or more(Note) Mean time to dangerous failure.
Details Hand protection type Min. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch)
Product Ultra-slim Light Curtain [Type 2 PLc SIL1]
Material Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloyMS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
Beam pitch 20 mm0.787 in
Accessories MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR25 (Test rod): 1 No.
Part Number SF2C-H24-P
Product name Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C
Power voltage 24 V DC plus or minus 20 % Ripple P-P 10 % or less
Response time OFF response: 20 ms or lessON response: 80 to 100 ms
Product Number SF2C-H24-P
Cable extension Extension up to total 50m is possible for 0.3mm2or more, cable
Operating range 0.1 to 3 m0.328 to 9.843 ft
Emitting element Infrared LED (Peak emission wavelength: 850 nm0.034 mil)
Pollution degree 3
Protective height 480 mm18.898 in
Operating altitude 2, 000 m6561.680 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
Ambient illuminance Incandescent light: 5,000 ℓx or less at the light-receiving face
Lockout output(SSD) - Maximum sink current: 60mA- Applied voltage: same as supply voltage (between the lockout output and +V)- Residual voltage: 2.5V or less (source current 60mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less
Min. sensing object ø25 mmø0.984 inopaque object
Test input function Incorporated
Control output(OSSD) - Maximum source current: 200mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5V or less (source current 200mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less
No. of beam channels 24
Effective aperture angle plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
Applicable standards:Japan JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508-1 to 3 (SIL 1)
Applicable standards:Europe EN 61496-1 (Type 2), EN ISO 13849-1:2015 (Category 2, PLc), EN 61508-1 to 3 (SIL 1), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
Interference prevention function Incorporated
Applicable standards:North America ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark.
Lockout output(SSD):Operation mode ON during normal operation, OFF during lockout(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
Control output(OSSD):Operation mode ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
Large multi-purpose indicator function Incorporated
Lockout output(SSD):Protection circuit Incorporated
Control output(OSSD):Protection circuit Incorporated
Applicable regulations and certifications CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification
Environmental resistance:Ambient humidity 30 to 85 % RH, Storage: 30 to 85 % RH
Environmental resistance:Shock resistance 300 m / s2acceleration (30 G approx.) in X, Y and Z directions three times each
Net weight (Total of emitter and receiver) 520 g approx.
Applicable standards:International standard IEC 61496-1 / 2 (Type 2), ISO 13849-1:2015 (Category 2, PLc), IEC 61508-1 to 3 (SIL 1)
Environmental resistance:Ambient temperature -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: - 25 to +60 ℃- 13 to +140 ℉
Environmental resistance:Degree of protection IP65, IP67 (IEC)
Environmental resistance:Vibration resistance 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each
Environmental resistance:Insulation resistance 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Environmental resistance:Voltage withstandability 1, 000 V AC for one min. between all supply terminals connected together and enclosure
Current consumption:Large multipurpose indicator lights up Emitter: 45 mA or lessReceiver: 40 mA or less
Current consumption:Large multipurpose indicator lights off Emitter: 35 mA or lessReceiver: 35 mA or less

Product Description

Cat.2 Safety Barrier (PLd SIL2) Ultra-narrow, Hand Protection, protected height 480 mm, PNP, 3m cable, IP67
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top