Key Specifications
: > 85 ms (230 V AC)
CSA: CAN/CSA-C22.2 No. 60950-1-07
Depth: 84 mm
Input: 4 kV (Test Level 4 - asymmetrical)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
> 85 ms (230 V AC)
CSA CAN/CSA-C22.2 No. 60950-1-07
Depth 84 mm
Input 4 kV (Test Level 4 - asymmetrical)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Width 35 mm
Height 90 mm
Output 2 kV (Test Level 3 - asymmetrical)
Voltage 10 V (Test Level 3)
Comments Criterion B
Derating 55 °C ... 70 °C (2.5 %/K)
Frequency 50 Hz
Rise time < 0.5 s (UOUT(10 % ... 90 %))
Efficiency typ. 88 % (120 V AC)
Input fuse 2.5 A (slow-blow, internal)
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Voltage dip 70 %
Input/Output asymmetrical
Output power 60 W
Product type Power supply
Screw thread M3
UL approvals UL/C-UL listed UL 508
Assembly note alignable: 0 mm horizontally, 30 mm vertically
Mounting type DIN rail mounting
Response time < 2 ms
Climatic class 3K22 (in accordance with EN 60721-3-3)
Inrush current < 30 A (typ.)
Product family UNO POWER
Additional text Class 3
Frequency range 80 MHz ... 1 GHz
Residual ripple < 30 mVPP(with nominal values)
Type of housing Polycarbonate
Article revision 04
Discharge in air 8 kV (Test Level 3)
Housing material Plastic
Number of phases 1.00
Protection class II (in closed control cabinet)
Stripping length 8 mm
Connection method Screw connection
Contact discharge 6 kV (Test Level 3)
Control deviation < 1 % (change in load, static 10 % ... 90 %)
Mounting position horizontal DIN rail NS 35, EN 60715
Number of periods 25 periods
AC frequency range 50 Hz ... 60 Hz
Protective circuit Transient surge protection; Varistor
Types of signaling LED
Current consumption typ. 1.3 A (100 V AC)
Degree of pollution 2
Foot latch material POM (Polyoxymethylene)
Input voltage range 85 V AC ... 264 V AC
Short-circuit-proof yes
Test field strength 10 V/m (Test Level 3)
Connection in series yes
Degree of protection IP20
Frequency range (fN) 50 Hz ... 60 Hz ±10 %
Mains buffering time > 20 ms (120 V AC)
Standard designation Requirement of the semiconductor industry with regard to mains voltage dips
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Output characteristic HICCUP
Standards/regulations EN 61000-4-2
Tightening torque max 0.6 Nm
Typical response time < 1 s
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Connection in parallel yes, for redundancy and increased capacity
Input voltage range AC 85 V AC ... 264 V AC
Nominal output voltage 24 V DC
Power factor (cos phi) 0.49
Tightening torque, min 0.5 Nm
With protective coating no
Standards/specifications SEMI F47 - 0706 (180 V AC)
Nominal power consumption 135.5 VA
Standard - Safe isolation DIN VDE 0100-410
MTBF (IEC 61709, SN 29500) > 785000 h (40 °C)
Feedback voltage resistance < 35 V DC
Nominal input voltage range 100 V AC ... 240 V AC
Nominal output current (IN) 2.5 A (-25 °C ... 55 °C)
Power loss nominal load max. < 7 W
Standard - Electrical safety IEC 62368-1 (SELV)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Inrush current integral (I2t) < 0.5 A2s (typ.)
Voltage type of supply voltage AC
Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
Insulation voltage input/output 4 kV AC (type test)
Conductor cross section AWG max. 14
Conductor cross section AWG min. 24
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 30 mm / 30 mm
SIL in accordance with IEC 61508 0
Maximum no-load power dissipation < 0.3 W
Standard - Safety of transformers EN 61558-2-16
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section, rigid min. 0.2 mm²
EMC requirements for noise emission EN 61000-6-3
EMC requirements for noise immunity EN 61000-6-1
Conductor cross section flexible max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
Ambient temperature (start-up type tested) -40 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Protection against overvoltage at the output (OVP) ≤ 35 V DC
Standard – Limitation of mains harmonic currents EN 61000-3-2
Flammability rating according to UL 94 (housing / terminal blocks) V0
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.2 mm²
Approval - requirement of the semiconductor industry with regard to mains voltage dips EN 61000-4-11
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)

Product Description

UNO POWER primary switching power supply for rail mounting, input: single-phase, output: 24 V DC/60 W
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top