Service time: Monday to Friday 9:00-18:00
UKH 240 - UKH 240 3010217 PHOENIX CONTACT High-current terminal block
In Stock Hot Product

UKH 240

UKH 240 3010217 PHOENIX CONTACT High-current terminal block

$44.76 USD
257 in stock
Key Specifications
: 1201659 E/AL-NS 32
Note: For a reliable contact of multi stranded conductors it is recommended to untwist multi stranded conductors.
Color: gray (RAL 7042)
Depth: 123.6 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
1201659 E/AL-NS 32
Note For a reliable contact of multi stranded conductors it is recommended to untwist multi stranded conductors.
Color gray (RAL 7042)
Depth 123.6 mm
Width 36 mm
Height 100 mm
Result Test passed
output (Permanent)
Spectrum Service life test category 2, bogie-mounted
ASD level 6.12 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 250 Hz
Potentials 1
Bridge data 270 A / 240 mm²
Pulse shape Half-sine
Revolutions 135
Acceleration 3.12g
Product type High current terminal block
Screw thread M10
Torque range 25 Nm ... 30 Nm
Mounting type NS 35/15
Rated current 350 A
Rated voltage 1100 V
Specification DIN EN 50155 (VDE 0115-200):2022-06
Identification  II 2 GD  Ex eb IIC Gb
Number of rows 1
Rotation speed 10 (+/- 2) rpm
Shock duration 30 ms
Depth on NS 32 129 mm
List of bridges Insertion bridge / EB 2-36/UKH / 0201401
Nominal current 415 A
Nominal voltage 1000 V
Open side panel No
Test directions X-, Y- and Z-axis
Article revision 11
Stripping length 40 mm
Time of exposure 30 s
Cross section AWG 3/0 ... 250 kcmil (converted acc. to IEC)
Tightening torque 25 ... 30 Nm
Contact resistance 0.03 mΩ
Depth on NS 35/15 131.5 mm
Degree of pollution 3
Dimensional drawing
Insulating material PA
Rated surge voltage 8 kV
Maximum load current 415 A (with 240 mm² conductor cross section)
Overvoltage category III
Nominal cross section 240 mm²
Number of connections 2
Test voltage setpoint 2.2 kV
Test duration per axis 5 h
Connection capacity AWG 2/0 ... 500 kcmil
DIN rail/fixing support NS 32/NS 35
Ex temperature increase 40 K (389 A/240 mm²)
Rated cross section AWG 500 kcmil
Ex-certified accessories 1201947 VDE-ISS 8
Rated insulation voltage 1000 V
Connection capacity rigid 70 mm² ... 240 mm²
Insulating material group I
Internal cylindrical gage B15
Operating temperature range -60 °C ... 110 °C
Connection capacity flexible 70 mm² ... 240 mm²
Conductor cross section rigid 70 mm² ... 240 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Conductor cross section/weight 70 mm²/10.4 kg
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level 2
Conductor cross section flexible 70 mm² ... 240 mm²
Connection in acc. with standard IEC 60947-7-1
Permissible humidity (operation) 20 % ... 90 %
at bridging with insertion bridge 690 V
Short-time withstand current 240 mm² 28.8 kA
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG] 3/0 ... 350 kcmil (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Cross-section with insertion bridge, rigid 240 mm²
Surface flammability NFPA 130 (ASTM E 162) passed
2 conductors with same cross section, solid 35 mm² ... 95 mm²
Cross-section with insertion bridge, flexible 185 mm²
2 conductors with same cross section, flexible 50 mm² ... 95 mm²
2 conductors with same cross section, stranded 50 mm² ... 95 mm²
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 13.78 W
2 conductors with the same cross-section AWG rigid 2 ... 3/0
2 conductors with the same cross-section AWG flexible 1/0 ... 3/0
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 70 mm² ... 185 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 70 mm² ... 185 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 35 mm² ... 50 mm²

Product Description

Current terminal, nominal voltage: 1000 V, nominal current: 415 A, number of connections: 2, connection type: Screw connection, Sizing cross-section: 240 mm², cross-section: 70 mm² - 240 mm², mounting
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top