Service time: Monday to Friday 9:00-18:00
UHGC1400L3P - UHGC1400L3P HG-C1400L3-P PANASONIC Compact Laser Displacement Sensor, 400mm+/-200mm, IO Link, cable 2m
In Stock Hot Product

UHGC1400L3P

UHGC1400L3P HG-C1400L3-P PANASONIC Compact Laser Displacement Sensor, 400mm+/-200mm, IO Link, cable 2m

$0.00 USD
4054 in stock
Key Specifications
Item: Specifications
Cable: Discrete wire type: 0.2 mm24-core PVC cable, 2 m6.562 ftlongM12 connector type: 0.2 mm24-core PVC cable with connector, 0.3 m0.984 ftlong
Remark: (Note):Supply voltage: 24 V DC, ambient temperature: +20℃+68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics.
Weight: 30 g approx. (without cable), 80 g approx. (including cable)
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Item Specifications
Cable Discrete wire type: 0.2 mm24-core PVC cable, 2 m6.562 ftlongM12 connector type: 0.2 mm24-core PVC cable with connector, 0.3 m0.984 ftlong
Remark (Note):Supply voltage: 24 V DC, ambient temperature: +20℃+68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics.
Weight 30 g approx. (without cable), 80 g approx. (including cable)
Details Discrete wire type
Product CMOS Type Micro Laser Distance Sensor
Material Enclosure: Aluminum die-cast, Front cover: Acrylic
Linearity ±0.2 % F.S.(Measuring distance 200 to 400 mm7.874 to 15.748 in)±0.3 % F.S.(Measuring distance 400 to 600 mm15.748 to 23.622 in)
Protection IP67(IEC)
Part Number HG-C1400L3-P
Light source Red semiconductor laser Class 2 [IEC / EN/ JIS / GB / KS / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm0.026 mil(Note:)This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
Product name CMOS type Micro Laser Distance Sensor HG-C1000L
Beam diameter ø500 μm19.685 milapprox.
Repeatability 300 μm11.811 mil(Measuring distance 200 to 400 mm7.874 to 15.748 in)800 μm31.496 mil(Measuring distance 400 to 600 mm15.748 to 23.622 in)
Response time Switchable between 1.5 ms / 5 ms / 10 ms
Control output PNP open-collector transistor• Maximum source current: 50 mA• Applied voltage: 30 V DC or less (Between control output to +V)• Residual voltage: 1.5 V or less (at 50 mA source current)• Leakage current: 0.1 mA or less
Product Number HG-C1400L3-P
Supply voltage 24 V DC ±10 % Ripple P-P 10 %
Cable extension Extension up to total 20 m65.617 ftis possible with 0.3 mm2, or more, cable.
Measuring range ±200 mm7.874 in
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Pollution degree 2
Shock resistance 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Operating altitude 2,000 m6561.680 ftor less
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face
Ambient temperature -10 to +45℃-14 to 113℉(No dew condensation or icing allowed), Storage: -20 to +60℃-4 to 140℉
Current consumption 40 mA or less (at 24 V DC supply voltage)
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each
Measurement center distance 400 mm15.748 in
Temprerature characteristics 0.03%F.S./℃
Control output:Output operation Switchable between either Light-ON or Dark-ON
Communication output (C/Q) : Baud rate COM3 (230.4 kbps)
Control output:Short-circuit protection Incorporated (auto reset type)
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification
Communication output (C/Q) : Process data 4 byte
Communication output (C/Q) : Minimum cycle time 1.0 ms
Communication output (C/Q) : IO-Link communication IO-Link Specification V1.1

Product Description

Micro Displacement Laser Sensor, measuring range 400mm. ± 200mm., repeatability 300μm. (from 200 to 300mm distance) and 800μm. (from 400 to 600mm distance), beam diameter approx. 500μm., PNP digital o
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top