Key Specifications
: 65 V DC
Fuse: M1 (normal blow)
Type: DIN rail module, one-piece
Depth: 96 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
65 V DC
Fuse M1 (normal blow)
Type DIN rail module, one-piece
Depth 96 mm
Width 12.5 mm
Height 82.5 mm
Fuse type Automatic device
Product type Thermomagnetic device circuit breakers
Screw thread M3
Humidity test 240 h, 95 % RH, 40 °C
Mounting type DIN rail: 35 mm
Rated voltage 250 V AC
Number of rows 2
Product family TMC
Nominal current 3 A
Nominal voltage 250 V AC
Open side panel No
Tripping method TM (thermomagnetic)
Rated current IN 3 A
Stripping length 12 mm
Auxiliary circuit 240 V AC / 1 A (Low-induction)
Cross section AWG 24 ... 10 (converted acc. to IEC)
Device resistance 0.057 Ω
Tightening torque 0.6 ... 0.8 Nm
Degree of pollution 2
Dielectric strength 3000 V AC (Actuation area)
Insulating material PA66
Number of positions 1
Rated surge voltage 2.5 kV
Degree of protection IP30 (Actuation area)
Overvoltage category II
Number of connections 4
Switching cycles, max. 10000 (At 1 x In, inductive)
Standards/specifications EN 60934
Insulating material group II
Internal cylindrical gage A3
Insulation resistance Riso > 100 MΩ (500 V DC)
Conductor cross section rigid 0.2 mm² ... 6 mm²
Ambient temperature (operation) -30 °C ... 60 °C
Conductor cross section flexible 0.2 mm² ... 4 mm²
Connection in acc. with standard IEC / EN
Short-circuit switching capacity 5000 A (UL 1077: 277 V AC)
Flammability rating according to UL 94 V-2
Rated short-circuit switching capacity Icn 400 A
2 conductors with same cross section, solid 0.2 mm² ... 0.75 mm²
2 conductors with same cross section, flexible 0.2 mm² ... 0.75 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.25 mm² ... 2.5 mm²
Conductor cross-section flexible (ferrule without plastic sleeve) 0.25 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.25 mm² ... 1 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 2.5 mm²

Product Description

Thermal-magnetic circuit breaker, 1-pos., normal blow, 1 N/O contact, with universal foot for mounting on NS 32 or NS 35
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top