Service time: Monday to Friday 9:00-18:00
STTBS 2,5-PE - STTBS 2,5-PE 3038480 PHOENIX CONTACT Protective conductor double-level terminal block
In Stock Hot Product

STTBS 2,5-PE

STTBS 2,5-PE 3038480 PHOENIX CONTACT Protective conductor double-level terminal block

$6.31 USD
1631 in stock
Key Specifications
: 1204517 SZF 1-0,6X3,5
Note: Please observe the current carrying capacity of the DIN rails.
Color: green-yellow
Width: 5.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
1204517 SZF 1-0,6X3,5
Note Please observe the current carrying capacity of the DIN rails.
Color green-yellow
Width 5.2 mm
Height 78 mm
Result Test passed
output (Permanent)
Spectrum Service life test category 2, bogie-mounted
ASD level 6.12 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 250 Hz
Pulse shape Half-sine
Acceleration 3.12g
Product type Ground terminal block
Mounting type NS 35/7,5
Specification DIN EN 50155 (VDE 0115-200):2008-03
Grounding foot Yes
Identification  II 2 G  Ex eb IIC Gb
Number of rows 2
Shock duration 18 ms
End cover width 2.2 mm
Open side panel Yes
Test directions X-, Y- and Z-axis
Article revision 09
Stripping length 8 mm ... 10 mm
Cross section AWG 28 ... 12 (converted acc. to IEC)
Depth on NS 35/15 62.5 mm
Degree of pollution 3
Depth on NS 35/7,5 55 mm
Insulating material PA
Rated surge voltage 6 kV
Overvoltage category III
Nominal cross section 2.5 mm²
Number of connections 4
Test duration per axis 5 h
Connection capacity AWG 28 ... 12
Rated cross section AWG 14
Ex-certified accessories 3038503 D-STTBS 2,5
Connection capacity rigid 0.08 mm² ... 4 mm²
Insulating material group I
Internal cylindrical gage A3
Operating temperature range -60 °C ... 110 °C
Connection capacity flexible 0.08 mm² ... 2.5 mm²
Conductor cross section rigid 0.08 mm² ... 4 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level 2
Conductor cross section flexible 0.08 mm² ... 2.5 mm²
Connection in acc. with standard IEC 60947-7-2
Permissible humidity (operation) 20 % ... 90 %
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG] 28 ... 14 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 0.77 W
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 2.5 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C

Product Description

Double-deck terminal block conductor protection, number of connections: 4, connection type: Spring connection, 1st and 2nd floor, cross-section: 0.08 mm² - 4 mm², mounting class: NS 35/7.5, NS 35/15,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide