Key Specifications
: max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
Fuse: G / 5 x 20
Color: black (RAL 9005)
Width: 6.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
Fuse G / 5 x 20
Color black (RAL 9005)
Width 6.2 mm
Height 61.5 mm
Result Test passed
Spectrum Service life test category 2, bogie-mounted
ASD level 6.12 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 250 Hz
Fuse type Glass / ceramics / ...
Potentials 1
Pulse shape Half-sine
Revolutions 135
Acceleration 3.12g
Product type Fuse terminal block
Mounting type NS 35/7,5
Specification DIN EN 50155 (VDE 0115-200):2008-03
Number of rows 1
Rotation speed 10 (+/- 2) rpm
Shock duration 18 ms
Nominal current 6.3 A
Nominal voltage 500 V
Open side panel No
Test directions X-, Y- and Z-axis
Article revision 13
Stripping length 8 mm ... 10 mm
Time of exposure 30 s
Cross section AWG 28 ... 10 (converted acc. to IEC)
Depth on NS 35/15 70 mm
Temperature cycles 192
Degree of pollution 3
Depth on NS 35/7,5 62.5 mm
Insulating material PA
Rated surge voltage 6 kV
Maximum load current 6.3 A (the current is determined by the fuse used)
Overvoltage category III
Nominal cross section 4 mm²
Number of connections 2
Test voltage setpoint 7.3 kV
Test duration per axis 5 h
Insulating material group I
Internal cylindrical gage A4
Maximum power dissipation max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
Conductor cross section rigid 0.08 mm² ... 6 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Conductor cross section/weight 0.14 mm² / 0.2 kg
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level 2
Conductor cross section flexible 0.08 mm² ... 4 mm²
Connection in acc. with standard IEC 60947-7-3
Permissible humidity (operation) 20 % ... 90 %
Requirement temperature-rise test Increase in temperature ≤ 45 K
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG] 28 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 1.02 W
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 4 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 1 mm²

Product Description

Fuse terminal block, fuse type: Glass/ceramic/..., fuse type: G/5 x 20, nominal voltage: 500 V, nominal current: 6.3 A, connection type: Spring connection, Sizing cross-section: 4 mm², cross-section:
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top