Service time: Monday to Friday 9:00-18:00
SOL-SC-1ST-0-DC-1MPPT-1300FS - SOL-SC-1ST-0-DC-1MPPT-1300FS 1137053 PHOENIX CONTACT String combiner box for photovoltaic systems up to 1000..
In Stock Hot Product

SOL-SC-1ST-0-DC-1MPPT-1300FS

SOL-SC-1ST-0-DC-1MPPT-1300FS 1137053 PHOENIX CONTACT String combiner box for photovoltaic systems up to 1000..

$0.00 USD
4269 in stock
Key Specifications
GTIN: 4063151074302
Orderkey: 1137053
(Drawings):
Packing unit: 1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4063151074302
Orderkey 1137053
(Drawings)
Packing unit 1
ETIM 4.0 (eCl@ss) EC000816
ETIM 5.0 (eCl@ss) EC000268
ETIM 6.0 (eCl@ss) EC000268
ETIM 7.0 (eCl@ss) EC000268
(Safety equipment) 2x 0.14 mm² ... 2.5 mm² (Remote indication contact, potential-free, max. 24 V DC)
Custom tariff number 85371098
System voltage (Drawings) 1000 V DC (Umax)
Number of outputs (Drawings) 1
eCl@ss 5.1 (Classifications) 27371890
eCl@ss 7.0 (Classifications) 27142422
eCl@ss 8.0 (Classifications) 27142422
eCl@ss 9.0 (Classifications) 27142422
Switching capacity (Drawings) 50 A (1000 V)
Protection class (Cable entry) I
eCl@ss 10.0.1 (Classifications) 27142422
Material cover/door (Cable entry) Polyester fiberglass reinforced
Degree of protection (Cable entry) IP65
Number of string inputs (Drawings) 1
Current per string (max.) (Drawings) 40 A (Imax)
Protection level Up (System parameter) ≤ 3.5 kV
Sealing area output (Safety equipment) 3 mm ... 6.5 mm
Type of cable entry (Safety equipment) Cable gland
Sealing area grounding (Safety equipment) 6 mm ... 12 mm (2x)
Surge protective device (System parameter) T1 / T2
Number of supported MPP trackers (Drawings) 1
Ambient temperature (operation) (Dimensions) -20 °C ... 40 °C
Rated operating current at DC-PV1 (Drawings) 40 A
Sealing area string input (Safety equipment) 3 mm ... 6.5 mm
Cable cross section output (Safety equipment) 2.5 mm² ... 6 mm²
Sealing area emergency stop (Safety equipment) 6 mm ... 12 mm
Cable cross section grounding (Safety equipment) 16 mm² (2x)
Cable cross section string input (Safety equipment) 2.5 mm² ... 6 mm²
Cable cross section emergency stop (Safety equipment) 3x 0.14 mm² ... 2.5 mm² (230 V AC)
Outer dimensions: width, height, depth (General data) 400 mm x 400 mm x 200 mm (Housing dimensions)
Connection diagramSchematic application drawing (Drawings)
Total discharge current Itotal(8/20) µs (System parameter) 40 kA
Total discharge current Itotal(10/350) µs (System parameter) 5 kA
Circuit diagramConnection of the remote indication contact on the surge protection (Drawings)

Product Description

String boxes for photovoltaic installations up to 1000 V DC for the connection of 1x 1 string. With surge protection (type 1/2), load disconnector for DC firefighters with remote access and push-in co
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Connection diagramSchematic application drawing

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top