Service time: Monday to Friday 9:00-18:00
SAC-4P-1,5-PUR/M12FS P - SAC-4P- 1,5-PUR/M12FS P 1442476 PHOENIX CONTACT Sensor/actuator cable
In Stock Hot Product

SAC-4P-1,5-PUR/M12FS P

SAC-4P- 1,5-PUR/M12FS P 1442476 PHOENIX CONTACT Sensor/actuator cable

$10.48 USD
988 in stock
Key Specifications
GTIN: 4046356535120
(Cable): No hazardous substances above threshold values
Orderkey: 1442476
Catalog page: Page 132 (PC-2011)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4046356535120
(Cable) No hazardous substances above threshold values
Orderkey 1442476
Catalog page Page 132 (PC-2011)
Packing unit 1 pc
(Dimensions) IP68
Country of origin PL (Poland)
China RoHS (Cable) Environmentally friendly use period: unlimited = EFUP-e
Custom tariff number 85444290
(Ambient conditions) 250 V DC
Contact material (General) CuSn
Material, knurls (General) Polyamide
Sealing material (General) NBR
Coding (Ambient conditions) A - standard
Torque (Ambient conditions) 0.4 Nm (M12 connector)
(Standards and Regulations) -25 °C ... 80 °C (cable, flexible installation)
Material of grip body (General) TPU, hardly inflammable, self-extinguishing
Standard designation (Material) M12 connector
Standards/regulations (Material) IEC 61076-2-101
Degree of protection (Dimensions) IP65
Contact carrier material (General) TPU GF
Contact surface material (General) Ni/Au
Rated voltage (Ambient conditions) 250 V AC
Status display (Ambient conditions) No
Weight per Piece (excluding packing) 46.600 g
Length of cable (Key Commercial Data) 1.5 m
Cable type (Standards and Regulations) PUR halogen-free black
Wire colors (Standards and Regulations) brown, white, blue, black
Acceleration (Standards and Regulations) 10 m/s²
Cable weight (Standards and Regulations) 30 kg/km
Degree of pollution (Ambient conditions) 3
Halogen-free (Standards and Regulations) in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions) 4
UL AWM style (Standards and Regulations) 20549 / 10493 (80°C/300 V)
Overall twist (Standards and Regulations) 4 wires, twisted
Overvoltage category (Ambient conditions) II
Insulation resistance (Ambient conditions) ≥ 100 MΩ
Standards/regulations (Ambient conditions) M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations) 22
Rated current at 40°C (Ambient conditions) 4 A
Traversing path (Standards and Regulations) 10 m
Traversing rate (Standards and Regulations) 3 m/s
Ambient temperature (operation) (Dimensions) -25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations) in accordance with UL 758/1581 FT2
Other resistance (Standards and Regulations) Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations) in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations) Li9Y11Y-HF
Conductor material (Standards and Regulations) Bare Cu litz wires
Special properties (Standards and Regulations) Flexible cable conduit capable
Test voltage, cable (Standards and Regulations) ≥ 3000 V
Conductor resistance (Standards and Regulations) ≤ 58 Ω/km
Flammability rating according to UL 94 (General) HB
Insertion/withdrawal cycles (Ambient conditions) ≥ 100
Flammability rating according to UL 94 (Material) HB
Insulation resistance (Standards and Regulations) ≥ 1 GΩ*km
Protective circuit/component (Ambient conditions) unwired
Thickness, insulation (Standards and Regulations) ≥ 0.21 mm
External sheath, color (Standards and Regulations) black-gray RAL 7021
Nominal voltage, cable (Standards and Regulations) ≤ 300 V
Outer sheath thickness (Standards and Regulations) approx. 0.5 mm
Outer sheath, material (Standards and Regulations) PUR
Conductor cross section (Standards and Regulations) 4x 0.34 mm²
Number of bending cycles (Standards and Regulations) 10000000
Cable type (abbreviation) (Standards and Regulations) PUR
External cable diameter D (Standards and Regulations) 4.2 mm ±0.15 mm
Material conductor insulation (Standards and Regulations) PP
Ambient temperature (operation) (Standards and Regulations) -40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations) 42x 0.10 mm
Core diameter including insulation (Standards and Regulations) 1.27 mm ±0.02 mm
Stripping length of the free conductor end (Key Commercial Data) 50 mm
Minimum bending radius, fixed installation (Standards and Regulations) 5 x D
Minimum bending radius, flexible installation (Standards and Regulations) 10 x D
Minimum bending radius, drag chain applications (Standards and Regulations) 10 x D

Product Description

Sensor/actuator cable, 4-pole, halogen-free PUR, greyish black RAL 7021, free cable end, to Straight connection female M12, coding: A, cable length: 1.5 m, with plastic knurling
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top