Key Specifications
: C2
ATEX:  II 1G Ex ia IIC T4...T6 Ga
Note: A2:2013
Type: Screw-in module
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
C2
ATEX  II 1G Ex ia IIC T4...T6 Ga
Note A2:2013
Type Screw-in module
Color Steel/stainless steel color
Depth 148 mm
IECEx Ex ia IIC T4...T6 Ga
Width 33.5 mm
Height 33.5 mm
Altitude ≤ 2000 m (amsl)
Product type Surge protection for MCR technology
Screw thread M3
Mounting type direct screw connection
Rated current 350 mA (50 °C)
Product family SURGETRAB
Open side panel No
Article revision 17
Housing material Zinc die-cast, surface bronzed and nickel-plated
Pollution degree 2
Connection method Screw connection
Tightening torque 0.6 Nm
Nominal voltage UN 24 V DC
Notes on operation When the bridge is disconnected, the shield connection is indirectly connected to the housing or reference potential.
Dimensional drawing
Direction of action Line-Line & Line-Earth Ground
Number of positions 3
Resistance per path 2.2 Ω ±10 %
max. input power Pi 3.00 W
Degree of protection IP67
Overvoltage category III
Residual current IPE ≤ 2 µA
Max. input current Ii 350 mA (T4 / ≤ 50 °C)
Max. input voltage Ui 30 V
Standards/regulations IEC 60664-1 / EN 60079-0 / EN 60079-11
Wire pairs per module 1
IEC test classification C1
Housing surface material nickel-plated
Max. surface temperature 135 °C (T4)
Standards/specifications EN 61643-21
Input attenuation aE, sym. typ. 0.5 dB (≤ 1 MHz / 50 Ω)
Conductor cross section AWG 26 ... 16
Max. internal inductance Li 1 µH
Response time tA(line-line) ≤ 1 ns
Insulation voltage to ground 500 V AC
Maximum inner capacitance Ci 2 nF
Response time tA(line-earth) ≤ 100 ns
Conductor cross section rigid 0.14 mm² ... 1.5 mm²
Maximum continuous voltage UC 30 V DC
Impulse durability (line-line) C1 - 1 kV / 500 A
Surge protection fault message none
Ambient temperature (operation) -40 °C ... 50 °C
Impulse durability (line-earth) C1 - 1 kV / 500 A
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
Response time tA (shield-ground) ≤ 100 ns
Impulse durability (shield-ground) C1 - 1  kV/500 A
Operating effective current ICat UC ≤ 10 µA
Voltage protection level Up(line-line) ≤ 50 V (C1 - 0.5 kV / 250 A)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Voltage protection level Up(line-earth) ≤ 1.4 kV (C1 - 1 kV / 500 A)
Pulse discharge current Iimp(10/350) µs 1 kA
Voltage protection level Up(shield-ground) ≤ 600 V (C1 - 0.5 kV / 250 A)
Residual voltage at In(conductor-conductor) ≤ 50 V
Alternating current carrying capacity (line-earth) 10 A - 1 s
Nominal discharge current In(8/20) µs (line-line) 10 kA
Cut-off frequency fg (3 dB), sym. in 50 Ω system typ. 6 MHz
Nominal pulse current Ian (10/1000) µs (line-line) 30 A
Residual voltage with Ian (10/1000) µs (line-line) ≤ 50 V
Cut-off frequency fg (3 dB), sym. in 150 Ω system typ. 2.5 MHz
Nominal discharge current In(8/20) µs (line-ground) 10 kA (per path)
Nominal pulse current Ian (10/1000) µs (line-earth) 100 A (per path)
Alternating current carrying capacity (shield-ground) 10 A - 1 s
Nominal discharge current In(8/20) µs (shield-ground) 10 kA (optional)
Nominal pulse current Ian (10/1000) µs (shield-ground) 100 A
Output voltage limitation at 1 kV/µs (line-line) spike ≤ 50 V
Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 1.4 kV (Direct grounding)
Output voltage limitation at 1 kV/µs (line-line) static ≤ 50 V
Max. discharge current Imax(8/20) µs maximum (line-line) 10 kA
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 1.4 kV (Direct grounding)
Max. discharge current Imax(8/20) µs maximum (line-earth) 10 kA (per path)
Output voltage limitation at 1 kV/µs (shield-ground) spike ≤ 600 V (optional)
Discharge surge current Imax(8/20) µs maximum (shield-ground) 10 kA

Product Description

Overvoltage protection. in IP67 screw-on module for circ measurement probes. intrinsically safe, direct mounting via 1/2'' NPT ext. thread, signal line cable gland, circ. of Protec. two-tier
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data