Key Specifications
: 4 A (380 - 440 V)
Color: silver/black
Width: 48 mm
Height: 48 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
4 A (380 - 440 V)
Color silver/black
Width 48 mm
Height 48 mm
Length 62.5 mm
Hole diameter 7 mm
Additional text Valid for networks with grounded neutral point, overvoltage category III, pollution degree 3
Switching angle 30 °
Breaking capacity 150 A (220 - 240 V)
Installation depth 33.50 mm
Rated surge voltage 6 kV
Maximum load current 20 A
Number of connections 4
Rotary switch function 1 > 0 < 2 with withdrawal on both sides
Rated continuous current 20 A
Rated insulation voltage 690 V
Switching program number S0214
Ambient temperature (operation) -35 °C ... 55 °C (Open, at 100% load, with peaks up to 60°C)
Conductor cross section AWG max. 14
Conductor cross section AWG min. 20
Conductor cross section solid max. 2.5 mm²
Conductor cross section solid min. 0.5 mm²
Rated short-time current resistance 140 A
Conductor cross section flexible max. 2.5 mm²
Conductor cross section flexible min. 0.75 mm²
Max. AWG conductor cross section, flexible 14
Min. AWG conductor cross section, flexible 18
2 conductors with same cross section, solid max. 2.5 mm²
2 conductors with same cross section, solid min. 0.5 mm²
2 conductors with same cross section, stranded max. 2.5 mm²
2 conductors with same cross section, stranded min. 0.75 mm²
IP immunity to short-circuiting with maximum backup fuse 25 A
Two conductors with the same cross section, AWG solid max. 14
Two conductors with the same cross section, AWG solid min. 20
Two conductors with the same cross section, AWG stranded, max. 14
Two conductors with the same cross section, AWG stranded, min. 18
Conductor cross section / stranded with ferrule with plastic sleeve min. 1.5 mm²
Conductor cross section / stranded, with ferrule with plastic sleeve max. 1.5 mm²
Conductor cross section / stranded with ferrule without plastic sleeve max. 2.5 mm²
Conductor cross section / stranded with ferrule without plastic sleeve min. 2.5 mm²
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, maximum 1.5 mm²
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, minimum 1.5 mm²
Rated operating current according to AC-21A (switching of ohmic loads including small overloads) 20 A
Switching power according to AC-4 (squirrel-cage motors: starting, reversing, plugging, inching) 0.55 kW (220 - 240 V; 3-phase, 3-pos.)
Switching power according to AC-23A (frequent switching of motors or other highly inductive loads) 3.7 kW (220 - 240 V; 3-phase, 3-pos.)
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, maximum 2.5 mm²
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, minimum 2.5 mm²
Rated operating current according to AC-15 (switching of solenoid drives, contactors, valves, pulling electromagnets) 5 A (220 - 240 V)
Rated operating current according to AC-22A (switching of mixed ohmic and inductive loads, including small overloads) 20 A (220 - 500 V)
Switching power according to AC-3 (squirrel-cage motors: direct starting, switching off motors during operation, star-delta startup (CH16B)) 3 kW (220 - 240 V; 3-phase, 3-pos.)