Service time: Monday to Friday 9:00-18:00
QUINT4-S-ORING/12-24DC/1X40 - QUINT4-S-ORING/12-24DC/1X40 2907752 PHOENIX CONTACT Redundancy module
In Stock Hot Product

QUINT4-S-ORING/12-24DC/1X40

QUINT4-S-ORING/12-24DC/1X40 2907752 PHOENIX CONTACT Redundancy module

$0.00 USD
4183 in stock
Key Specifications
: 24 V DC
LED: yes
Time: 186000 h
Depth: 125 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
24 V DC
LED yes
Time 186000 h
Depth 125 mm
I/O/S asymmetrical
Input 2 kV (Test Level 4 - asymmetrical)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Width 32 mm
Height 130 mm
Output 2 kV (Test Level 4 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Current 40 A
Default open
Voltage 10 V (Test Level 3)
Comments Criterion B
Derating 60 °C ... 70 °C (2.5 %/K)
Frequency 16.67 Hz
Efficiency typ. 99.1 % (12 V DC)
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Temperature 40 °C
UIn< 8 V DC LED off, input voltage not present or short circuit at redundancy module output
UIn> 8 V DC LED lights up green, input voltage present
Hood version Galvanized sheet steel, free from chrome (VI)
Product type Redundancy module
Screw thread M4
UL approvals UL/C-UL listed UL 508
Assembly note alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Mounting type DIN rail mounting
Climatic class 3K3 (in acc. with EN 60721)
Noise emission Additional basic standard EN 61000-6-5 (immunity in power station)
Product family QUINT S-ORING
Additional text UIN
Frequency range 80 MHz ... 1 GHz
Type of housing Aluminum (AlMg3)
Article revision 03
Discharge in air 15 kV (Test Level 4)
Housing material Metal
Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
Protection class III
Stripping length 10 mm
Connection method Screw connection
Contact discharge 8 kV (Test Level 4)
Mounting position horizontal DIN rail NS 35, EN 60715
Input current ISFB 215 A (15 ms)
Output description Group contact
Types of signaling Relay contact, floating, current limited
Current consumption 40 A
Degree of pollution 2
Dimensional drawing
Input voltage range 8 V DC ... 30 V DC
Test field strength 20 V/m (Test Level 3)
Connection in series no
Degree of protection IP20
Input current IStatic 45 A (40 °C)
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Shipbuilding approval DNV GL
Standards/regulations EN 61000-4-2
Tightening torque max 1.5 Nm
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Input current IDynamic 60 A (5 s)
Maximum inrush current ≤ 100 mA (short-circuit-proof)
Nominal output voltage UIn- 0.1 V
Tightening torque, min 1.2 Nm
DNV GL noise radiation Class B
Redundancy modul faulty LED lights up red, redundancy module needs to be factory tested
Conducted noise emission EN 55016
Maximum switching voltage max. 30 V AC/DC
Standard - Safe isolation DIN VDE 0100-410
Dynamic Boost (IDyn.Boost) 60 A (5 s)
MTBF (IEC 61709, SN 29500) > 25297000 h (25 °C)
Nominal input current (IN) 40 A (-40 °C ... 60 °C)
Static Boost (IStat.Boost) 45 A
Transient surge protection Varistor
Voltage drop, input/output 0.1 V
Nominal input voltage range 12 V DC ... 24 V DC
Nominal output current (IN) 40 A
Reverse polarity protection < yes60 V
Power loss nominal load max. 6.5 W (IOUT= 40 A)
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Typical national grid voltage 12 V DC
DNV GL conducted interference Class A
Selective Fuse Breaking (ISFB) 215 A (15 ms)
Voltage type of supply voltage DC
Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Conductor cross section AWG max. 6
Conductor cross section AWG min. 20
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 40 mm / 20 mm
SIL in accordance with IEC 61508 0
Conductor cross section, rigid max. 16 mm²
Conductor cross section, rigid min. 0.5 mm²
EMC requirements for noise emission EN 61000-6-3
EMC requirements for noise immunity EN 61000-6-1
Conductor cross section flexible max. 16 mm²
Conductor cross section flexible min. 0.5 mm²
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Insulation voltage input, output / housing 500 V DC
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Flammability rating according to UL 94 (housing / terminal blocks) V0
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 16 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 16 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.5 mm²
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)

Product Description

Active single QUINT redundancy module for rail mounting, 12 to 24 VDC input, 12 to 24 VDC / 1 x 40 A output, including UTA 107/30 rail universal adapter mounted
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top