Service time: Monday to Friday 9:00-18:00
QUINT4-S-ORING/12-24DC/1X40/VP - QUINT4-S-ORING/12-24DC/1X40/VP 1043418 PHOENIX CONTACT Active QUINT single redundancy module for DIN rail mo..
In Stock Hot Product

QUINT4-S-ORING/12-24DC/1X40/VP

QUINT4-S-ORING/12-24DC/1X40/VP 1043418 PHOENIX CONTACT Active QUINT single redundancy module for DIN rail mo..

$0.00 USD
4350 in stock
Key Specifications
GTIN: 4055626607474
Orderkey: 1043418
(Drawings):
(Standards): UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4055626607474
Orderkey 1043418
(Drawings)
(Standards) UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Catalog page Page 305 (C-4-2019)
Packing unit 1
(Input data) 6 W (IOUT= 40 A)
(Output data) > 3379000 h (60 °C)
Depth (Drawings) 125 mm
Width (Drawings) 32 mm
ETIM 5.0 (eCl@ss) EC000683
ETIM 6.0 (eCl@ss) EC000683
ETIM 7.0 (eCl@ss) EC000683
Height (Drawings) 130 mm
Diagram (Drawings)
Custom tariff number 85049090
Derating (Input data) 60 °C ... 70 °C (2.5%/K)
REACh SVHC (EMC data) Lead 7439-92-1
Screw thread (General) M4
(Conformance/approvals) 60 Hz
Block diagram (Drawings)
Efficiency (Output data) typ. 99 % (12 V DC)
Net weight (Output data) 0.4 kg
UL approvals (Standards) UL/C-UL listed UL 508
Stripping length (General) 10 mm
Climatic class (Dimensions) 3K3 (in acc. with EN 60721)
Connection method (General) Screw connection
eCl@ss 8.0 (Classifications) 27371010
eCl@ss 9.0 (Classifications) 27371010
I/O/S (Conformance/approvals) asymmetrical
Input (Conformance/approvals) 1 kV (Test Level 4 - symmetrical)
Output (Conformance/approvals) 1 kV (Test Level 2 - symmetrical)
Protection class (Output data) III
Signal (Conformance/approvals) 1 kV (Test Level 2 - asymmetrical)
Mounting position (Output data) horizontal DIN rail NS 35, EN 60715
Voltage (Conformance/approvals) 10 V (Test Level 3)
Comments (Conformance/approvals) Criterion A
Degree of pollution (Dimensions) 2
Installation height (Dimensions) ≤ 5000 m (> 2000 m, observe derating)
Connection in series (Input data) No
Degree of protection (Dimensions) IP20
Frequency (Conformance/approvals) 16.67 Hz
Output voltage range (Input data) 8 V DC ... 27.5 V DC
Degree of protection (Output data) IP20
Assembly instructions (Output data) alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Criterion A (Conformance/approvals) Normal operating behavior within the specified limits.
Criterion B (Conformance/approvals) Temporary impairment to operational behavior that is corrected by the device itself.
Screw thread (Connection data, input) M4
Noise emission (Conformance/approvals) EN 55016
Additional text (Conformance/approvals) 60 s
Dynamic Boost (IDyn.Boost) (Input data) 60 A (5 s)
Frequency range (Conformance/approvals) 0.15 MHz ... 80 MHz
Static Boost (IStat.Boost) (Input data) 45 A
Current consumption (Ambient conditions) 40 A
Discharge in air (Conformance/approvals) 15 kV (Test Level 4)
Input voltage range (Ambient conditions) 8 V DC ... 27.5 V DC (SELV)
MTBF (IEC 61709, SN 29500) (Output data) > 13486000 h (25 °C)
Nominal output current (IN) (Input data) 40 A
Contact discharge (Conformance/approvals) 8 kV (Test Level 4)
Power loss nominal load max. (Input data) 6.5 W (IOUT= 40 A)
Stripping length (Connection data, input) 10 mm
Conductor cross section AWG max. (General) 6
Conductor cross section AWG min. (General) 20
Connection method (Connection data, input) Screw connection
Depth with alternative assembly (Drawings) 35 mm
Nominal input current (Ambient conditions) 40 A (-40 °C ... 60 °C)
Stripping length (Connection data, output) 8 mm
Width with alternative assembly (Drawings) 122 mm
Connection method (Connection data, output) Push-in connection
Height with alternative assembly (Drawings) 130 mm
Selective Fuse Breaking (ISFB) (Input data) 215 A (15 ms)
Test field strength (Conformance/approvals) 30 A/m
Ambient temperature (operation) (Dimensions) -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General) 16 mm²
Conductor cross section solid min. (General) 0.5 mm²
Low Voltage Directive (Conformance/approvals) Conformance with Low Voltage Directive 2014/35/EC
Conductor cross section flexible max. (General) 16 mm²
Conductor cross section flexible min. (General) 0.5 mm²
DNV GL noise radiation (Conformance/approvals) Class B
Electrostatic discharge (Conformance/approvals) EN 61000-4-2
Fast transients (burst) (Conformance/approvals) EN 61000-4-4
Conducted noise emission (Conformance/approvals) EN 55016
Electromagnetic HF field (Conformance/approvals) EN 61000-4-3
Nominal input voltage range (Ambient conditions) 12 V DC ... 24 V DC
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Electromagnetic compatibility (Conformance/approvals) Conformance with EMC Directive 2014/30/EU
DNV GL conducted interference (Conformance/approvals) Class A
Conductor cross section AWG max. (Connection data, input) 6
Conductor cross section AWG min. (Connection data, input) 20
Standard - Safe isolation (Connection data for signaling) DIN VDE 0100-410
Conductor cross section AWG max. (Connection data, output) 16
Conductor cross section AWG min. (Connection data, output) 24
Conductor cross section solid max. (Connection data, input) 16 mm²
Conductor cross section solid min. (Connection data, input) 0.5 mm²
Max. permissible relative humidity (operation) (Dimensions) ≤ 100 % (at 25 °C, non-condensing)
Conductor cross section solid max. (Connection data, output) 1.5 mm²
Conductor cross section solid min. (Connection data, output) 0.2 mm²
Standard - Electrical safety (Connection data for signaling) EN 60950-1/VDE 0805 (SELV)
Conductor cross section flexible max. (Connection data, input) 16 mm²
Conductor cross section flexible min. (Connection data, input) 0.5 mm²
Conductor cross section flexible max. (Connection data, output) 1.5 mm²
Conductor cross section flexible min. (Connection data, output) 0.2 mm²
Protection against overvoltage at the output (OVP) (Input data) ≤ 30 V DC
Standard – Safety extra-low voltage (Connection data for signaling) IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment (Connection data for signaling) EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling) EN 50178/VDE 0160 (PELV)

Product Description

Active single QUINT redundancy module for rail mounting, protective varnish, 12 to 24 V DC input, 12 to 24 V DC / 1 x 40 A output, including universal adapter for UTA 107/30 rail mounted
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top