Service time: Monday to Friday 9:00-18:00
QUINT-DIODE/48DC/40 - QUINT-DIODE/48DC/40 2866585 PHOENIX CONTACT Redundancy module, with protective coating
In Stock Hot Product

QUINT-DIODE/48DC/40

QUINT-DIODE/48DC/40 2866585 PHOENIX CONTACT Redundancy module, with protective coating

$0.00 USD
4478 in stock
Key Specifications
: < 60 V DC (Umax)
LED: no
ATEX:  II 3 G Ex nA II T4
Depth: 102 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
< 60 V DC (Umax)
LED no
ATEX  II 3 G Ex nA II T4
Depth 102 mm
Shock 30g, 18 ms in accordance with IEC 60068-2-27
Width 62 mm
Height 84 mm
Temp code T4 (70 °C)
Efficiency > 97 %
Product type Redundancy module
Screw thread M4
UL approvals UL/C-UL listed UL 508
Assembly note alignable: horizontal 20 mm, vertical 50 mm
Input voltage 48 V DC (UN)
Mounting type DIN rail mounting
Noise emission EN 55011
Product family QUINT DIODE
Type of housing AIMg (hood), GD-ZnAICu (cooling unit)
Horizontal pitch 3.4 Div.
Housing material Metal
Protection class II
Stripping length 10 mm
Connection method Screw connection
Mounting position horizontal and vertical DIN rail NS 35, EN 60715
Degree of pollution 2
Input voltage range 10 V DC ... 60 V DC
Connection in series no
Degree of protection IP20
Maximum current Imax 2x 19 A (6 mm² at 40°C)
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Tightening torque max 1.5 Nm
Vibration (operation) 3 Hz ... 15 Hz, amplitude ±2.5 mm; 15 Hz ... 100 Hz, 2.3g according to IEC 60068-2-6
Input voltage range DC 10 V DC ... 60 V DC
Nominal output voltage 47.3 V DC (Input/output voltage drop of 48 V ... 0.7 V )
Tightening torque, min 1.2 Nm
Nominal input current (IN) 2x 20 A
Transient surge protection Transil diode
Voltage drop, input/output approx. 0.7 V
Nominal output current (IN) 40 A
Reverse polarity protection < yes120 V
Power loss nominal load max. 28 W
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Insulation voltage input / PE 1 kV
Insulation voltage output / PE 1 kV
Voltage type of supply voltage DC
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating,  -25 ... 60°C)
Conductor cross section AWG max. 6
Conductor cross section AWG min. 20
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm
Conductor cross section, rigid max. 16 mm²
Conductor cross section, rigid min. 0.5 mm²
EMC requirements for noise emission EN 61000-6-3
EMC requirements for noise immunity EN 61000-6-1
Conductor cross section flexible max. 10 mm²
Conductor cross section flexible min. 0.5 mm²
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Declaration of conformity in acc. with EN 60079-15  II 3 G Ex nA II T4 X
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)

Product Description

QUINT-DIODE/48DC/40 Redundancy Module
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top