Service time: Monday to Friday 9:00-18:00
PV-SET 3ST-SPD-FESD-SC - PV-SET 3ST-SPD-FESD-SC 2901860 PHOENIX CONTACT Surge protection device set
In Stock Hot Product

PV-SET 3ST-SPD-FESD-SC

PV-SET 3ST-SPD-FESD-SC 2901860 PHOENIX CONTACT Surge protection device set

$0.00 USD
3288 in stock
Key Specifications
: PV T2
Note: 2011
Type: Installation housing
Depth: 122 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
PV T2
Note 2011
Type Installation housing
Depth 122 mm
Width 250 mm
Height 370 mm
Screw thread M2
Mounting type Surface/Wall mounting
Set comprises 1774674 PV-CF-S 2,5-6 (+)
Cover material Polycarbonate, transparent
Impact strength IK08
Housing material Polycarbonate, glass-fiber-reinforced
Pollution degree 2
Protection class II
Rated current IN 0.5 A
Response time tA ≤ 25 ns
Stripping length 7 mm
Connection method MC 1,5/3
Tightening torque 2 lbf-in. ... 4 lbf-in.
Ambient conditions A, B
Nominal current IN 24 A DC (total)
Nominal voltage UN 1000 V DC
Switching function Changeover contact, 1-pos.
Direction of action (L+)-PE & (L-)-PE & (L+)-(L-)
Degree of protection IP65
Overvoltage category III
Residual current IPE ≤ 20 µA DC
Rated load current IL 24 A DC
Standards/regulations EN 50539-11
Tightening torque, min 0.25 Nm
IEC test classification PV T1
Standards/specifications IEC 61439-2
Rated operating voltage Ue 230 V AC
Conductor cross section AWG 30 ... 14 (UL)
Max. operating current Imax 1.5 A AC (250 V AC)
Open circuit voltage UOCSTC 830 V DC (Solar generator)
Response time tA(L+) - (L-) ≤ 25 ns
Response time tA(L+/L-) - PE ≤ 25 ns
Short-circuit current ISCSTC 8 A DC (per string)
Standby power consumption PC ≤ 25 mVA
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -20 °C ... 45 °C
Recommended backup fuse maximum not required
Maximum operating voltage UmaxDC 30 V DC
Maximum operating voltage Umax.AC 250 V AC
Conductor cross section, rigid max. 1.5 mm²
Conductor cross section, rigid min. 0.14 mm²
Max. backup fuse with branch wiring not required
Rated surge voltage resistance Uimp 8 kV
Conductor cross section flexible max. 1.5 mm²
Conductor cross section flexible min. 0.14 mm²
Flammability rating according to UL 94 V2 Gehäuse
Nominal discharge current In(8/20) µs 15 kA
Voltage protection level Up(L+) - (L-) ≤ 3.5 kV
Voltage protection level Up(L+/L-) - PE ≤ 3.5 kV
Maximum discharge current Imax(8/20) µs 40 kA
Maximum continuous operating voltage UCPV 1000 V DC
Total discharge current Itotal(8/20) µs 40 kA
Total discharge current Itotal(10/350) µs 5 kA
Impulse discharge current (10/350) µs, peak value limp 5 kA

Product Description

Surge protection in IP65 housing for the DC side of an inverter for three-string photovoltaic systems up to 1000 V DC. With fire service switch.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top