Key Specifications
: IP65
Type: Installation housing
Color: light grey RAL 7035
Depth: 122 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
IP65
Type Installation housing
Color light grey RAL 7035
Depth 122 mm
Width 200 mm
Height 200 mm
Cable gland M20
Screw thread M2
Sealing area 5 mm ... 13 mm
Mounting type Surface/Wall mounting
Cover material Polycarbonate, transparent
Impact strength IK08
Horizontal pitch 9 Div.
Housing material Polycarbonate, glass-fiber-reinforced
Protection class II
Response time tA ≤ 25 ns
Stripping length 7 mm
Connection method MC 1,5/3
Tightening torque 0.25 Nm
Ambient conditions A, B
Connector material PA
Switching function PDT, 1-pos.
Direction of action (L+)-PE & (L-)-PE & (L+)-(L-)
Degree of protection IP65
Residual current IPE ≤ 25 µA
Rated load current IL 80 A DC
Standards/regulations IEC 61439-2 2011
IEC test classification PV T1
Conductor cross section AWG 30 ... 14 (UL)
Max. operating current Imax 1.5 A AC (250 V AC)
Open circuit voltage UOCSTC 830 V DC (Solar generator)
Rated insulation voltage Ui 1000 V DC
Residual voltage (L+) - (L-) ≤ 3.5 kV (at In)
Short-circuit current ISCSTC 25 A DC
Standby power consumption PC ≤ 25 mVA
Residual voltage (L+/L-) - PE ≤ 3.5 kV (at 15 kA)
Surge protection fault message optical
Ambient temperature (operation) -20 °C ... 40 °C
Recommended backup fuse maximum Not required
Conductor cross section AWG max. 14
Conductor cross section AWG min. 30
Maximum operating voltage UmaxDC 30 V DC
Maximum operating voltage Umax.AC 250 V AC
Conductor cross section solid max. 1.5 mm²
Conductor cross section solid min. 0.14 mm²
Max. backup fuse with branch wiring Not required
Rated surge voltage resistance Uimp 6 kV
Conductor cross section flexible max. 1.5 mm²
Conductor cross section flexible min. 0.14 mm²
Max. discharge current Imax(8/20) µs 40 kA
Flammability rating according to UL 94 V2 (Gehäuse / Deckel)
Nominal discharge current In(8/20) µs 15 kA
Voltage protection level Up(L+) - (L-) ≤ 3.5 kV
Voltage protection level Up(L+/L-) - PE ≤ 3.5 kV
Standards for cearances and creepage distances EN 50539-11