Service time: Monday to Friday 9:00-18:00
PTWE 6-2/11 - PTWE 6-2/11 3069834 PHOENIX CONTACT Test terminal strip
In Stock Hot Product

PTWE 6-2/11

PTWE 6-2/11 3069834 PHOENIX CONTACT Test terminal strip

$0.00 USD
4374 in stock
Key Specifications
: 0.3 kA
Note: Dimensions panel cutout see appendix.
Color: gray (RAL 7042)
Depth: 56.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
0.3 kA
Note Dimensions panel cutout see appendix.
Color gray (RAL 7042)
Depth 56.5 mm
Pitch 8.2 mm
Width 122.3 mm
Height 81 mm
Result Test passed
Spectrum Service life test category 2, bogie-mounted
ASD level 6.12 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 250 Hz
Potentials 11
Pulse shape Half-sine
Revolutions 135
Acceleration 3.12g
Product type Test terminal strip
Mounting type Wall mounting
Specification DIN EN 50155 (VDE 0115-200):2008-03
Number of rows 1
Rotation speed 10 rpm
Shock duration 18 ms
Nominal voltage 400 V AC/DC
Open side panel No
Test directions X-, Y- and Z-axis
Stripping length 12 mm
Time of exposure 30 s
Cross section AWG 20 ... 8 (converted acc. to IEC)
Temperature cycles 192
Test surge voltage 5 kV
Dimensional drawing
Insulating material PA
Number of positions 11
Rated surge voltage 4 kV
Test force setpoint 5 N
Maximum load current 30 A (with 6 mm² conductor cross section)
Overvoltage category III
Nominal cross section 6 mm²
Number of connections 22
Test voltage setpoint 4.8 kV
Test duration per axis 5 h
Insulating material group I
Internal cylindrical gage A5
Conductor cross section rigid 0.5 mm² ... 10 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Conductor cross section/weight 0.5 mm² / 0.3 kg
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Conductor cross section flexible 0.5 mm² ... 6 mm²
Connection in acc. with standard IEC 60947-7-1
Requirement temperature-rise test Increase in temperature ≤ 45 K
Short-time withstand current 4 mm² 0.5 kA
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG] 20 ... 10 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 1.31 W
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.5 mm² ... 6 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.5 mm² ... 6 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 1.5 mm²

Product Description

Test pin strip, rated voltage: 400 V, number of connections: 22, number of poles: 11, connection type: Push-in connection, 1st floor, Sizing section: 6 mm², cross-section: 0.5 mm² - 10 mm², mounting c
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide