Key Specifications
: For versions with 6 or 7 connections, it is enough to place one DIN rail adapter centrally per block and place flange elements after every other block.
Note: When aligning several blocks, it is recommended to either place a DIN rail adapter underneath the connection point or a flange element between the blocks.
Color: yellow (RAL 1018)
Depth: 17.7 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
For versions with 6 or 7 connections, it is enough to place one DIN rail adapter centrally per block and place flange elements after every other block.
Note When aligning several blocks, it is recommended to either place a DIN rail adapter underneath the connection point or a flange element between the blocks.
Color yellow (RAL 1018)
Depth 17.7 mm
Width 12.5 mm
Height 21.6 mm
Result Test passed
Potentials 1
Product type Distributor terminal block
Mounting type for snapping onto a DIN rail adapter
Number of rows 1
Nominal current 17.5 A
Nominal voltage 450 V
Open side panel No
Article revision 03
Stripping length 8 mm ... 10 mm
Time of exposure 30 s
Cross section AWG 26 ... 14 (converted acc. to IEC)
Notes on operation the blocks can be bridged with one another via the conductor shaft, for corresponding plug-in bridges, see accessories
Degree of pollution 3
Insulating material PA
Rated surge voltage 6 kV
Maximum load current 22 A
Overvoltage category III
Maximum total current 26 A
Nominal cross section 1.5 mm²
Number of connections 6
DIN rail/fixing support NS 35/NS 15
Rated cross section AWG 14
Insulating material group I
Internal cylindrical gage A1 / B1
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level 6
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
Connection in acc. with standard IEC 60998-2-2
Permissible humidity (operation) 20 % ... 90 %
Conductor cross section, rigid [AWG] 26 ... 14 (converted acc. to IEC)
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG] 26 ... 16 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Maximum power dissipation for nominal condition 0.56 W
Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 1.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 1.5 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C

Product Description

Distribution block, internally bridged, rated voltage: 450 V, rated current: 17.5 A, number of connections: 6, connection type: Push-in connection, cross-section: 0.14 mm² - 2.5 mm², mounting class: i
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top