PTFIX 4/6X1,5-G RD - PTFIX 4/6X1,5-G RD 1047480 PHOENIX CONTACT Distribution block, nom. voltage: 450 V, nominal current: 17.5 A,..
In Stock Hot Product

PTFIX 4/6X1,5-G RD

PTFIX 4/6X1,5-G RD 1047480 PHOENIX CONTACT Distribution block, nom. voltage: 450 V, nominal current: 17.5 A,..

$0.00 USD
4970 in stock
Key Specifications
GTIN: 4055626665856
Orderkey: 1047480
(Drawings):
Catalog page: Page 436 (C-1-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4055626665856
Orderkey 1047480
(Drawings)
Catalog page Page 436 (C-1-2019)
Packing unit 1 pc
Width (General) 19 mm
Color (Drawings) red
Height (General) 18.7 mm
Length (General) 21.6 mm
Country of origin PL (Poland)
ETIM 5.0 (eCl@ss) EC000897
ETIM 6.0 (eCl@ss) EC000897
ETIM 7.0 (eCl@ss) EC000897
(Connection data) IEC 60998-2-2
ASD level (Drawings) 6.12 (m/s2)2/Hz
Custom tariff number 85369010
Shock form (Drawings) Half-sine
Minimum order quantity 20 pc
Acceleration (Drawings) 30g
Connection (Dimensions) Feed-in stage
Test spectrum (Drawings) Service life test category 2, bogie-mounted
Shock duration (Drawings) 18 ms
Test frequency (Drawings) f1= 5 Hz to f2= 250 Hz
Open side panel (Drawings) No
Test directions (Drawings) X-, Y- and Z-axis (pos. and neg.)
Number of levels (Drawings) 1
Shock test result (Drawings) Test passed
eCl@ss 8.0 (Classifications) 27141120
eCl@ss 9.0 (Classifications) 27141120
Nominal current IN (Drawings) 41 A
Nominal voltage UN (Drawings) 500 V
Stripping length (Dimensions) 10 mm ... 12 mm
Connection method (Dimensions) Push-in connection
Degree of pollution (Drawings) 3
Insulating material (Drawings) PA
Rated surge voltage (Drawings) 6 kV
Maximum load current (Drawings) 41 A (with 6 mm² conductor connection)
Overvoltage category (Drawings) III
Maximum total current (Drawings) 41 A
Nominal cross section (Drawings) 1.5 mm²
Number of connections (Drawings) 7
Result of thermal test (Drawings) Test passed
Test duration per axis (Drawings) 5 h
Insulating material group (Drawings) I
Weight per Piece (excluding packing) 9.000 g
Internal cylindrical gage (Dimensions) A3
Nominal cross section feed-in (Drawings) 6 mm²
NF F16-101, NF F10-102 Class F (Drawings) 2
NF F16-101, NF F10-102 Class I (Drawings) 2
Number of shocks per direction (Drawings) 3
Test specification, shock test (Drawings) DIN EN 50155 (VDE 0115-200):2018-05
Oxygen index (DIN EN ISO 4589-2) (Drawings) >32 %
Conductor cross section AWG max. (Dimensions) 10
Conductor cross section AWG min. (Dimensions) 24
Connection in acc. with standard (Dimensions) IEC 60998-2-2
Conductor cross section solid max. (Dimensions) 6 mm²
Conductor cross section solid min. (Dimensions) 0.2 mm²
Flame test method (DIN EN 60695-11-10) (Drawings) V0
Flammability rating according to UL 94 (Drawings) V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Drawings) passed
Conductor cross section flexible max. (Dimensions) 4 mm²
Conductor cross section flexible min. (Dimensions) 0.2 mm²
Connection in acc. with standard (Connection data) IEC 60998-2-2
Oscillation, broadband noise test result (Drawings) Test passed
Surface flammability NFPA 130 (ASTM E 162) (Drawings) passed
Max. AWG conductor cross section, flexible (Dimensions) 10
Min. AWG conductor cross section, flexible (Dimensions) 24
Flammability rating according to UL 94 (Connection data) V0
Static insulating material application in cold (Drawings) -60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Drawings) Test passed
Calorimetric heat release NFPA 130 (ASTM E 1354) (Drawings) 27,5 MJ/kg
Test specification, oscillation, broadband noise (Drawings) DIN EN 50155 (VDE 0115-200):2018-05
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Drawings) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Drawings) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Drawings) HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Drawings) HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Drawings) passed
Relative insulation material temperature index (Elec., UL 746 B) (Drawings) 130 °C
Proof of thermal characteristics (needle flame) effective duration (Drawings) 30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Drawings) 125 °C
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) 4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) 0.2 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) 0.2 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) 1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) 0.5 mm²

Product Description

Distribution block, nominal voltage: 450 V, nominal current: 17.5 A, number of connections: 7, connection type: Push-in connection, Branch, cross-section: 0.14 mm² - 2.5 mm², Collective connection, Di
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Circuit diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide