Service time: Monday to Friday 9:00-18:00
PTCB E1 24DC/0.5A NO - PTCB E1 24DC/0.5A NO 1361051 PHOENIX CONTACT Electronic Appliance Protection Switches
In Stock Hot Product

PTCB E1 24DC/0.5A NO

PTCB E1 24DC/0.5A NO 1361051 PHOENIX CONTACT Electronic Appliance Protection Switches

$0.00 USD
3386 in stock
Key Specifications
: Repeated hard short circuits can reduce the melting integral of the integrated backup fuse.
EMC: A
Fuse: electronic
Note: Connection for signal line tested in accordance with EN 61000-4-4 with 1 kV; if necessary, customer must provide appropriate protective measures
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Repeated hard short circuits can reduce the melting integral of the integrated backup fuse.
EMC A
Fuse electronic
Note Connection for signal line tested in accordance with EN 61000-4-4 with 1 kV; if necessary, customer must provide appropriate protective measures
Type DIN rail module, one-piece
Depth 55.6 mm (incl. DIN rail 7.5 mm)
Width 6.2 mm
Height 105.8 mm
Altitude ≤ 3000 m up to 52 °C (amsl)
Humidity B
Material PBT
Enclosure A
Vibration B
Efficiency > 98.5 %
Temperature A
Product type Device circuit breakers
Voltage drop 0.28 V (at 0.5 A)
Humidity test 96 h, 95 % RH, 40 °C
Mounting type DIN rail: 35 mm
Rated voltage 24 V DC
Shutdown time ≤ 600 ms
Identification UL/C-UL Listed UL 508
Product family PTCB
Channel LED off off (Channel switched off)
Channel LED red lit (Channel switched off, over- or undervoltage active)
Connection name Remote indication circuit
No. of channels 1
Tripping method E (electronic)
Pollution degree 2
Protection class III
Rated current IN 15 A DC (Total current input)
Stripping length 8 mm
Channel LED green lit (Channel switched on)
Connection method Push-in connection
Cross section AWG (converted acc. to IEC)
Fail-safe element 4 A DC
Operating current 100 mA DC
Operating voltage 10 V DC ... 30 V DC
Power dissipation typ. 0.1 W (No-load operation)
Shock (operation) 30g (IEC 60068-2-27, Test Ea)
Channel LED yellow flashing (Programming mode active)
Switching function N/O contact
Dielectric strength max. 35 V DC (Load circuit)
Dimensional drawing
Feedback resistance max. 35 V DC
Number of positions 1
Rated surge voltage 0.5 kV
Degree of protection IP20
Max. capacitive load 5.7 mF (Depending on the current setting and the short-circuit current available)
Required backup fuse Only required if Imaxof the power supply > the short-circuit switching capacity. Integrated failsafe element.
Temperature derating 15 A (Total current at 60°C)
Measuring tolerance I ± 7 %
Vibration (operation) 10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
Overvoltage switch-off ≥ 30.5 V DC (active)
Undervoltage switch-off ≤ 9.2 V DC (active)
Standards/specifications EN 61000-6-2
Active current limitation typ. 1,1 x IN
Closed circuit current I0 typ. 5 mA
MTBF (IEC 61709, SN 29500) 28514399 h (at 25 °C with 21 % load)
Module initialization time 40 ms
Conductor cross section AWG 24 ... 12
Rated current (pre-adjusted) 0.5 A
Conductor cross section rigid 0.2 mm² ... 4 mm²
Ambient temperature (operation) -30 °C ... 60 °C
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Short-circuit switching capacity 300 A
Flammability rating according to UL 94 V-0
Ambient temperature (storage/transport) -40 °C ... 70 °C
Waiting time after switch off of a channel 5 s (at overload / short circuit)
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.2 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 0.2 mm² ... 2.5 mm²

Product Description

Single-channel, electronic device protection for 12-24 V DC loads. Fixed nominal current value: 0.5 A. With remote signaling and active current limitation. Can be combined with CLIPLINE terminal block
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top