Service time: Monday to Friday 9:00-18:00
PT 5-HF-12 DC-ST - PT 5-HF-12 DC-ST 2838775 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 5-HF-12 DC-ST

PT 5-HF-12 DC-ST 2838775 PHOENIX CONTACT Surge protection plug

$0.00 USD
3625 in stock
Key Specifications
GTIN: 4017918480646
Orderkey: 2838775
(General): D1 - 2.5 kA
Catalog page: Page 147 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4017918480646
Orderkey 2838775
(General) D1 - 2.5 kA
Catalog page Page 147 (C-4-2017)
Packing unit 10 pc
Country of origin DE (Germany)
(Connection data) IEC 61643-21 A2:2012
Custom tariff number 85363010
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Rated current (General) 450 mA (45°C)
Type (Ambient conditions) Male
Color (Ambient conditions) jet black RAL 9005
Response time tA (General) ≤ 500 ns
Depth (Key Commercial Data) 52 mm
Width (Key Commercial Data) 17.7 mm
Height (Key Commercial Data) 45 mm
Nominal voltage UN (General) 12 V DC
Capacity (line-line) (General) typ. 30 pF
Residual current IPE (General) ≤ 5 µA (with PT 2X2-BE)
Resistance in series (General) 2.2 Ω ±10 %
Degree of protection (Dimensions) IP20
IEC test classification (General) C1
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) on base element
Input attenuation aE, sym. (General) typ. 0.3 dB (≤ 5 MHz / 100 Ω)
Max. required back-up fuse (General) 500 mA (T)
Weight per Piece (excluding packing) 25.600 g
Housing material (Ambient conditions) PA 6.6
Stripping length (Protective circuit) 8 mm
Connection method (Protective circuit) Screw connection (in connection with the base element)
Horizontal pitch (Key Commercial Data) 1 Div.
Tightening torque (Protective circuit) 0.8 Nm
Maximum continuous voltage UC (General) 14 V DC
Degree of pollution (Ambient conditions) 2
Direction of action (Ambient conditions) Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Impulse durability (line-line) (General) C2 - 10 kV/5 kA
Number of positions (Ambient conditions) 5
Surge protection fault message (General) none
Impulse durability (line-earth) (General) C2 - 10 kV/5 kA
Overvoltage category (Ambient conditions) III
Standards/specifications (Connection data) EN 61643-21 A2:2013
Complete module depth (Key Commercial Data) 65.5 mm
Complete module width (Key Commercial Data) 17.7 mm
Residual voltage at In(line-line) (General) ≤ 25 V
Ambient temperature (operation) (Dimensions) -40 °C ... 85 °C
Complete module height (Key Commercial Data) 90 mm
Residual voltage at In(line-earth) (General) ≤ 40 V (with PT 2X2-BE)
Operating effective current ICat UC (General) ≤ 5 µA
Conductor cross section AWG (Protective circuit) 24 ... 12
Voltage protection level Up(line-line) (General) ≤ 80 V (C1 - 1 kV/500 A)
Voltage protection level Up(line-earth) (General) ≤ 85 V (C1 - 1 kV / 500 A with PT 2X2-BE)
Conductor cross section solid (Protective circuit) 0.2 mm² ... 4 mm²
Pulse discharge current Iimp(10/350) µs (General) 2.5 kA
Total discharge current Itotal(8/20) µs (General) 20 kA
Residual voltage at In(line-signalground) (General) ≤ 25 V (with PT 2X2-BE)
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Conductor cross section flexible (Protective circuit) 0.2 mm² ... 2.5 mm²
Voltage protection level Upstatic (line-line) (General) ≤ 25 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-signalground) (General) ≤ 50 V (C3 - 25 A with PT 2X2-BE)
Voltage protection level Upstatic (line-earth) (General) ≤ 45 V (C2 - 10 kV / 5 kA with PT 2X2-BE)
Flammability rating according to UL 94 (Ambient conditions) V-0
Nominal discharge current In(8/20) µs (line-line) (General) 10 kA
Cut-off frequency fg (3 dB), sym. in 100 Ohm system (General) typ. 60 MHz
Nominal discharge current In(8/20) µs (line-earth) (General) 20 kA (in total)
Nominal pulse current Ian (10/1000) µs (line-line) (General) 67 A
Residual voltage with Ian (10/1000) µs (line-line) (General) ≤ 25 V
Voltage protection level Upstatic (line-signalground) (General) ≤ 25 V (C2 - 10 kV / 5 kA with PT 2X2-BE)
Output voltage limitation at 1 kV/µs (line-line) spike (General) ≤ 55 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 55 V (with PT 2X2-BE)
Output voltage limitation at 1 kV/µs (line-line) static (General) ≤ 25 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General) 10 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General) ≤ 25 V (with PT 2X2-BE)
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 20 kA (in total)
Residual voltage with Ian (10/1000) µs (line-signalground) (General) ≤ 25 V
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions) From SW rev. 1.10

Product Description

PT plug-in protection with HF (high frequency) protection circuit for 4 signal conductors. Rated voltage: 12 V DC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top