Service time: Monday to Friday 9:00-18:00
PT 4X1-12AC-ST - PT 4X1-12AC-ST 2838348 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 4X1-12AC-ST

PT 4X1-12AC-ST 2838348 PHOENIX CONTACT Surge protection plug

$0.00 USD
3801 in stock
Key Specifications
: C2
Note: 2000
Type: Male
Depth: 52 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
C2
Note 2000
Type Male
Depth 52 mm
Width 17.7 mm
Height 45 mm
Product type Surge protection for MCR technology
Screw thread M3
Mounting type on base element
Rated current 300 mA (45 °C)
Product family PLUGTRAB PT
Open side panel No
Horizontal pitch 1 Div.
Housing material PA 6.6
Pollution degree 2
Connection method Screw connection (in connection with the base element)
Tightening torque 0.8 Nm
Nominal voltage UN 12 V AC
Dimensional drawing
Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Resistance per path 4.7 Ω 10 %
Degree of protection IP20
Overvoltage category III
Residual current IPE ≤ 1 µA (with PT 4X1-BE)
Capacity (Core-Earth) 2.5 nF
Complete module depth 65.5 mm
Complete module width 17.7 mm
Standards/regulations VDE 0110-1 / IEC 60664-1
VDE requirement class C1
Complete module height 90 mm
IEC test classification C1
Standards/specifications IEC 61643-21
Max. required back-up fuse 315 mA (T)
Conductor cross section AWG 24 ... 12
Input attenuation aE, asym. 0.5 dB (≤ 700 kHz)
Response time tA(line-earth) ≤ 1 ns
Conductor cross section rigid 0.2 mm² ... 4 mm²
Maximum continuous voltage UC 18 V DC
Surge protection fault message none
Ambient temperature (operation) -40 °C ... 85 °C
Impulse durability (line-earth) C2 - 10 kV / 5 kA
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Operating effective current ICat UC ≤ 5 µA
Flammability rating according to UL 94 V-0
Voltage protection level Up(line-earth) ≤ 70 V (C2 - 10 kV / 5 kA)
Residual voltage at In(conductor-ground) ≤ 31 V
Pulse discharge current Iimp(10/350) µs 2.5 A (per path)
Total discharge current Itotal(8/20) µs 20 kA
Nominal discharge current In(8/20) µs (line-ground) 10 kA
Nominal pulse current Ian (10/1000) µs (line-earth) 49 A
Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 30 V
Cut-off frequency fg (3 dB), asym. (PE) in 50 Ω system typ. 4 MHz
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 25 V
Max. discharge current Imax(8/20) µs maximum (line-earth) 10 kA
Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00

Product Description

Protective plug PT with protective circuit for 4 conductors of signal circuits grounded on one side. Nominal voltage: 12 V AC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide