Service time: Monday to Friday 9:00-18:00
PT 2X2-FF-ST - PT 2X2-FF-ST 2800755 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 2X2-FF-ST

PT 2X2-FF-ST 2800755 PHOENIX CONTACT Surge protection plug

$0.00 USD
4241 in stock
Key Specifications
: C2
Note: 2009
Type: Male
Color: black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
C2
Note 2009
Type Male
Color black (RAL 9005)
Depth 52 mm
Width 17.7 mm
Height 45 mm
Altitude ≤ 2000 m (amsl)
Product type Surge protection for information technology
Mounting type on base element
Rated current 1.6 A
Product family PLUGTRAB PT
Open side panel No
Article revision 09
Horizontal pitch 1 Div.
Housing material PA
Pollution degree 2
Connection method Screw connection (in connection with the base element)
Nominal voltage UN 32 V DC
Dimensional drawing
Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Number of positions 5
Resistance per path ≤ 1 Ω
Degree of protection IP20
Overvoltage category III
Residual current IPE ≤ 5 µA (with PT 4-BE)
Complete module depth 65.5 mm
Complete module width 17.7 mm
Standards/regulations DIN VDE 0110-1 / IEC 60664-1
VDE requirement class C1
Wire pairs per module 2
Complete module height 90 mm
IEC test classification C1
Standards/specifications EN 61643-21/A1
Response time tA(line-line) ≤ 1 ns
Response time tA(line-earth) ≤ 100 ns
Maximum continuous voltage UC 36 V DC
Impulse durability (line-line) C3 - 25 A
Surge protection fault message none
Ambient temperature (operation) -40 °C ... 85 °C
Impulse durability (line-earth) C1 - 1 kV / 500 A
Operating effective current ICat UC ≤ 5 µA
Flammability rating according to UL 94 V0
Voltage protection level Up(line-line) ≤ 75 V (C3 - 25 A)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Voltage protection level Up(line-earth) ≤ 1.3 kV (C1 - 1.5 kV)
Pulse discharge current Iimp(10/350) µs 1 kA
Nominal discharge current In(8/20) µs (line-line) 100 A
Nominal pulse current Ian (10/1000) µs (line-line) 23 A
Nominal discharge current In(8/20) µs (line-ground) 10 kA
Output voltage limitation at 1 kV/µs (line-line) spike ≤ 75 V
Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 1.3 kV (with PT 4-BE)
Output voltage limitation at 1 kV/µs (line-line) static ≤ 75 V
Max. discharge current Imax(8/20) µs maximum (line-line) 100 A
Max. discharge current Imax(8/20) µs maximum (line-earth) 10 kA

Product Description

PLUGTRAB, Plug-in Surge Protection for Foundation Fieldbus
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top