PT 2X1- 5DC-ST - PT 2X1- 5DC-ST 2856061 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 2X1- 5DC-ST

PT 2X1- 5DC-ST 2856061 PHOENIX CONTACT Surge protection plug

$0.00 USD
3514 in stock
Key Specifications
GTIN: 4017918599249
Orderkey: 2856061
(General): D1 - 2.5 kA
Catalog page: Page 112 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4017918599249
Orderkey 2856061
(General) D1 - 2.5 kA
Catalog page Page 112 (C-4-2017)
Packing unit 10 pc
Country of origin DE (Germany)
(Connection data) UL 497B
Custom tariff number 85363010
(Ambient conditions) IEC 60664-1
Rated current (General) 300 mA (45°C)
Type (Ambient conditions) Male
Color (Ambient conditions) black
Depth (Key Commercial Data) 51.7 mm
Width (Key Commercial Data) 17.5 mm
Height (Key Commercial Data) 44.8 mm
Nominal voltage UN (General) 5 V DC
Residual current IPE (General) ≤ 1 µA (with PT 2X1+F-BE)
Resistance in series (General) 4.7 Ω (1-2/5-6/7-8/11-12)
Capacity (line-earth) (General) 3 nF
VDE requirement class (General) C1
Degree of protection (Dimensions) IP20
IEC test classification (General) C1
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) on base element
Max. required back-up fuse (General) 315 mA (T)
Weight per Piece (excluding packing) 16.570 g
Housing material (Ambient conditions) PA 6.6
Input attenuation aE, asym. (General) 0.5 dB (≤ 200 kHz)
Stripping length (Protective circuit) 8 mm
Connection method (Protective circuit) Screw connection (in connection with the base element)
Horizontal pitch (Key Commercial Data) 1 Div.
Response time tA(line-earth) (General) ≤ 1 ns
Tightening torque (Protective circuit) 0.8 Nm
Maximum continuous voltage UC (General) 6 V DC
Standards/regulations (Connection data) IEC 61643-21
Direction of action (Ambient conditions) Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Surge protection fault message (General) none
Impulse durability (line-earth) (General) C2 - 10 kV/5 kA
Standards/specifications (Connection data) IEC 61643-21 2000
Complete module depth (Key Commercial Data) 65.5 mm
Complete module width (Key Commercial Data) 17.7 mm
Ambient temperature (operation) (Dimensions) -40 °C ... 85 °C
Complete module height (Key Commercial Data) 90 mm
Residual voltage at In(line-earth) (General) ≤ 10 V
Operating effective current ICat UC (General) ≤ 1 mA
Conductor cross section AWG (Protective circuit) 24 ... 12
Voltage protection level Up(line-earth) (General) ≤ 50 V (C2 - 10 kV / 5 kA)
Conductor cross section solid (Protective circuit) 0.2 mm² ... 4 mm²
Pulse discharge current Iimp(10/350) µs (General) 2.5 kA (per path)
Total discharge current Itotal(8/20) µs (General) 20 kA
Conductor cross section flexible (Protective circuit) 0.2 mm² ... 2.5 mm²
Flammability rating according to UL 94 (Ambient conditions) V-0
Nominal discharge current In(8/20) µs (line-earth) (General) 10 kA
Nominal pulse current Ian (10/1000) µs (line-earth) (General) 125 A
Residual voltage with Ian (10/1000) µs (line-earth) (General) ≤ 12 V
Cut-off frequency fg (3 dB), asym. (PE) in 50 Ohm system (General) typ. 1 MHz
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 14 V
Output voltage limitation at 1 kV/µs (line-earth) static (General) ≤ 10 V
Standards for cearances and creepage distances (Ambient conditions) VDE 0110-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 10 kA
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions) From SW rev. 1.00

Product Description

Plug-in surge protection for base element, coarse and fine protection for two signal conductors with common reference potential, coarse protection against longitudinal voltage to earth. Execution: 5 V
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top