PT 2,5-PE/L RD/L BU/L - PT 2,5-PE/L RD/L BU/L 1336370 PHOENIX CONTACT Ground terminal, number of connections: 8, number of poles: 4,..
In Stock Hot Product

PT 2,5-PE/L RD/L BU/L

PT 2,5-PE/L RD/L BU/L 1336370 PHOENIX CONTACT Ground terminal, number of connections: 8, number of poles: 4,..

$7.19 USD
1432 in stock
Key Specifications
: The max. load current must not be exceeded by the total current of all connected conductors.
Note: When establishing a connection on the open housing side of a feed-through modular terminal block of the same series and size, the block must be provided with a cover if the expected insulation voltage is >690 V.
Color: gray
Width: 5.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
The max. load current must not be exceeded by the total current of all connected conductors.
Note When establishing a connection on the open housing side of a feed-through modular terminal block of the same series and size, the block must be provided with a cover if the expected insulation voltage is >690 V.
Color gray
Width 5.2 mm
Height 142.4 mm
Result Test passed
Spectrum Service life test category 1, class B, body mounted
ASD level 0.964 (m/s²)²/Hz
Frequency f1= 5 Hz to f2= 150 Hz
Pulse shape Half-sine
Acceleration 0.58g
Product type Ground terminal block
Mounting type NS 35/7,5
Specification DIN EN 50155 (VDE 0115-200):2022-06
Number of rows 4
Shock duration 30 ms
End cover width 2.2 mm
Nominal current 18 A
Nominal voltage 500 V
Open side panel Yes
Test directions X-, Y- and Z-axis
Stripping length 8 mm ... 10 mm
Cross section AWG (converted acc. to IEC)
Depth on NS 35/15 76.1 mm
Degree of pollution 3
Depth on NS 35/7,5 68.6 mm
Insulating material PA
Number of positions 4
Rated surge voltage 6 kV
Maximum load current 20 A (with 4 mm² conductor cross-section)
Overvoltage category III
Nominal cross section 2.5 mm²
Number of connections 8
Test duration per axis 5 h
Insulating material group I
Internal cylindrical gage A3
Conductor cross section rigid 0.14 mm² ... 4 mm²
Ambient temperature (assembly) -5 °C ... 70 °C
Number of shocks per direction 3
Ambient temperature (actuation) -5 °C ... 70 °C
Ambient temperature (operation) -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Number of connections per level 2
Conductor cross section flexible 0.14 mm² ... 4 mm²
Connection in acc. with standard IEC 60947-7-2
Conductor cross section, rigid [AWG] 20 ... 12 (converted acc. to IEC)
Flammability rating according to UL 94 V0
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG] 26 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport) 30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162) passed
Static insulating material application in cold -60 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 2.5 mm²

Product Description

Protective conductor terminal, number of connections: 8, number of positions: 4, connection method: Push-in connection, Protective conductor connection, Rated cross section: 2.5 mm2, cross section: 0.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide