Service time: Monday to Friday 9:00-18:00
PSR-PS23-1NO-1NC-24VDC-SC - PSR-PS23-1NO-1NC-24VDC-SC 2702663 PHOENIX CONTACT Coupling relay for SIL 3 high and low-demand applications,..
In Stock Hot Product

PSR-PS23-1NO-1NC-24VDC-SC

PSR-PS23-1NO-1NC-24VDC-SC 2702663 PHOENIX CONTACT Coupling relay for SIL 3 high and low-demand applications,..

$0.00 USD
4555 in stock
Key Specifications
GTIN: 4055626280233
Orderkey: 2702663
(Drawings):
Catalog page: Page 250 (C-6-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4055626280233
Orderkey 2702663
(Drawings)
Catalog page Page 250 (C-6-2019)
Depth (Note) 102.5 mm
Packing unit 1 pc
Width (Note) 6.8 mm
Height (Note) 93.1 mm
(Power supply) 4 A gL/gG (for low-demand applications)
Torque (General) 0.5 Nm ... 0.6 Nm
Country of origin DE (Germany)
ETIM 5.0 (eCl@ss) EC001449
ETIM 6.0 (eCl@ss) EC001449
ETIM 7.0 (eCl@ss) EC001449
Net weight (Times) 70.162 g
Relay type (Times) Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205)
pluggable (General) no
Custom tariff number 85364900
(Ambient conditions) > 1 s (at A1-A2; high test pulse rate)
Housing color (Times) yellow
Mounting type (Times) DIN rail mounting
Screw thread (General) M3
Status display (Times) 1 x green LED
Block diagram (Drawings)
Housing material (Times) PBT
Mounting position (Times) vertical or horizontal
Output fuse (Power supply) 6 A gL/gG
Output name (Power supply) Enabling current path
Stripping length (General) 12 mm
Connection method (General) Screw connection
Contact type (Power supply) 1 enabling current path
(Standards and Regulations) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Degree of protection (Times) IP20
eCl@ss 5.1 (Classifications) 27371901
eCl@ss 6.0 (Classifications) 27371800
eCl@ss 7.0 (Classifications) 27371819
eCl@ss 8.0 (Classifications) 27371819
eCl@ss 9.0 (Classifications) 27371819
Assembly instructions (Times) See derating curve
Designation (Connection data) EN 50156-2
Inrush current (Power supply) min. 3 mA
Maximum altitude (Dimensions) ≤ 2000 m (Above sea level)
Nominal operating mode (Times) 100% operating factor
Contact material (Power supply) AgSnO2
Stop category (Connection data) 0
Filter time (Ambient conditions) max. 2 ms (at A1-A2 in the event of voltage dips at Us)
Number of outputs (Power supply) 1 (safety-related N/O contacts: 13/14)
Sq. Total current (Power supply) 36 A2(observe derating)
Switching voltage (Power supply) min. 12 V AC/DC
Operating voltage display (Times) 1 x yellow LED
Output description (Power supply) 2 N/O contacts in series, without delay, floating
Switching capacity (Power supply) min. 60 mW
Switching frequency (Power supply) max. 1 Hz
Utilization restriction (Drawings) EMC: class A product, see manufacturer's declaration in the download area
Inrush current (Ambient conditions) typ. 120 mA (Δt <10 ms at Us)
Weight per Piece (excluding packing) 160.000 g
(Safety-related characteristic data) Class I, Div. 2, Groups A, B, C, D, T4
China RoHS (Standards and Regulations) Environmentally Friendly Use Period = 50
Mechanical service life (Power supply) 10x 106cycles
REACh SVHC (Standards and Regulations) Lead 7439-92-1
(Relay outputs: enabling current path) max. 100 mA
Protective circuit (Ambient conditions) Serial protection against polarity reversal 35 V suppressor diode (A1-A2)
ATEX (Safety-related characteristic data)  II 3 G Ex nA nC IIC T4 Gc
Conductor cross section AWG max. (General) 12
Conductor cross section AWG min. (General) 26
IECEx (Safety-related characteristic data) Ex nA nC IIC T4 Gc
Limiting continuous current (Power supply) 6 A (High demand)
Shock (Safety-related characteristic data) 15g
Ambient temperature (operation) (Dimensions) -40 °C ... 70 °C (observe derating)
Conductor cross section solid max. (General) 2.5 mm²
Conductor cross section solid min. (General) 0.2 mm²
Power consumption at US (Ambient conditions) typ. 1.08 W
Safety Integrity Level (SIL) (Connection data) 3 (Reference IEC 61508)
Conductor cross section flexible max. (General) 2.5 mm²
Conductor cross section flexible min. (General) 0.2 mm²
Conformance (Safety-related characteristic data) CE-compliant
Designation (Safety-related characteristic data) Air clearances and creepage distances between the power circuits
Output fuse (Relay outputs: enabling current path) 150 mA Fast-blow
Output name (Relay outputs: enabling current path) Confirmation current path
Contact type (Relay outputs: enabling current path) 1 confirmation current path
Min. degree of protection of inst. location (Times) IP54
UL, USA/Canada (Safety-related characteristic data) cULus
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 85 °C
Rated control supply current IS (Ambient conditions) typ. 45 mA
Inrush current (Relay outputs: enabling current path) min. 1 mA
Contact material (Relay outputs: enabling current path) AgCuNi, + Au
Degree of pollution (Safety-related characteristic data) 2
Number of outputs (Relay outputs: enabling current path) 1 (safety-related N/C contacts: 21/22)
Switching voltage (Relay outputs: enabling current path) min. 5 V DC
Output description (Relay outputs: enabling current path) 2 N/C contacts in series, without delay, floating
Overvoltage category (Safety-related characteristic data) III
Switching capacity (Relay outputs: enabling current path) min. 20 mW
Max. permissible humidity (storage/transport) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Standards/regulations (Safety-related characteristic data) DIN EN 50178, EN 60079-15
Switching frequency (Relay outputs: enabling current path) max. 1 Hz
Vibration (operation) (Safety-related characteristic data) 10 Hz ... 150 Hz, 2g
Max. permissible relative humidity (operation) (Dimensions) 75 % (on average, 85% infrequently, non-condensing)
Rated control circuit supply voltage US (Ambient conditions) 24 V DC -20 % / +25 % (A1/A2)
Switching capacity according to IEC 60947-5-1 (Power supply) 4 A (24 V (DC13))
Rated insulation voltage (Safety-related characteristic data) 250 V AC
Mechanical service life (Relay outputs: enabling current path) 10x 106cycles
Environmental simulation test (Safety-related characteristic data) ISA-S71.04 (G3)
Limiting continuous current (Relay outputs: enabling current path) 100 mA
Rated surge voltage/insulation (Safety-related characteristic data) Basic insulation 4 kV between all current paths and housing
Recovery time (Relay outputs: return current/signaling current path) 500 ms
Typical pickup time at US (Relay outputs: return current/signaling current path) < 70 ms (with Uswhen controlled via A1)
Typical release time at US (Relay outputs: return current/signaling current path) < 30 ms (when controlled via A1)

Product Description

SIL 3 coupling relay for high and low demand applications, couples digital output signals to the periphery, 1 trip circuit, 1 acknowledgment circuit, Safe-State-Off applications, test pulse filter, fi
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top