Key Specifications
: Light grid
Note: G3
Depth: 113.6 mm
Shock: 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Light grid
Note G3
Depth 113.6 mm
Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
Width 45.2 mm
Height 107.74 mm
Voltage 24 V DC (via A1)
pluggable yes
Interfaces DIN rail TBUS for connection to the master module, not supplied as standard
Ohmic load min. 50 Ω (Observe limiting continuous current)
Application Emergency stop
Designation A1/A2
Filter time typ. 5 ms (at A1 in the event of voltage dips at Us)
Test pulses < 120 µs (Test pulse width of low test pulses)
Cable length max. 100 m (per input)
Product type Safety device
Restart time min. 5 s (Boot time)
Mounting type DIN rail mounting
Response time see user manual
Stop category 0
Identification CE-compliant
Inrush current < 14.4 A (Δt = 0.5 ms at Us)
Status display 1 x LED (green), 1 x LED (orange), 1 x LED (blue)
Leakage current max. 500 µA
Error indication 2 x LED (red)
Housing material Polyamide PA non-reinforced
Maximum altitude ≤ 2000 m (Above sea level)
Number of inputs 8
Protection class III
Stripping length 10 mm
Connection method Push-in connection
Mounting position vertical or horizontal
Number of outputs 4
Output description Safety-related digital outputs
Protective circuit Serial protection against polarity reversal
Transmission speed 100 Mbps (Full duplex)
Current consumption typ. 3.7 mA (typically with US)
Discharging circuit Yes, internal
Max. inductive load max. 2.4 mH
Switching frequency max. 1/4 x tCycle[Hz]
Degree of protection IP20
Max. capacitive load max. 820 nF
Assembly instructions Observe derating
Number of connections 2
Vibration (operation) 10 Hz ... 150 Hz, 2g
Communication protocol PROFINET
Maximum inrush current 1.1 A (Δt = 3 s  at Us)
Nominal operating mode 100% operating factor
Nominal output voltage 24 V DC (Supply via A1)
Performance level (PL) e (2-channel wiring)
Power consumption at US typ. 2.88 W (Outputs inactive)
Description of the input Safety-related digital inputs
Rated insulation voltage 250 V AC
Short-circuit protection no
Operating voltage display 1 x green LED
Conductor cross-section AWG 24 ... 16
Limiting continuous current 400 mA (per channel)
Nominal output voltage range 18.5 V DC ... 28.1 V DC (US- 0,7 V)
Safety Integrity Level (SIL) 3
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Input current range "0" signal < 0.2 mA
Input voltage range "0" signal 0 V DC ... 5 V DC
Input voltage range "1" signal 11 V DC ... 28.8 V DC
Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
Ambient temperature (operation) -10 °C ... 70 °C (observe derating)
Rated control supply current IS 120 mA (RMS typ. inactive for all outputs)
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Output voltage when switched off < 0.3 V
Ambient temperature (storage/transport) -20 °C ... 85 °C
Rated control circuit supply voltage US 19.2 V DC ... 28.8 V DC
Min. degree of protection of inst. location IP54
Max. permissible humidity (storage/transport) 95 % (non-condensing)
Max. permissible overall conductor resistance max. 1.2 kΩ (Input and reset circuit at US)
Max. permissible relative humidity (operation) 95 % (non-condensing)
Maximum power dissipation for nominal condition 9.85 W (with max. permissible load)

Product Description