Service time: Monday to Friday 9:00-18:00
PLT-SEC-T3-60-FM-UT - PLT-SEC-T3-60-FM-UT 2907917 PHOENIX CONTACT Type 3 surge protection device
In Stock Hot Product

PLT-SEC-T3-60-FM-UT

PLT-SEC-T3-60-FM-UT 2907917 PHOENIX CONTACT Type 3 surge protection device

$0.00 USD
3299 in stock
Key Specifications
GTIN: 4055626257426
Orderkey: 2907917
(General): ≤ 8.4 mVA (at UC)
Packing unit: 5 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4055626257426
Orderkey 2907917
(General) ≤ 8.4 mVA (at UC)
Packing unit 5 pc
(Dimensions) ≤ 6000 m (operating voltage remote contact ≤ 150 V)
Country of origin DE (Germany)
(Connection data) DC
(UL specifications) 48 V DC (1 A)
Custom tariff number 85363030
(Ambient conditions) PA 6.6-FR
(Protective circuit) (DC+/DC-) - PE
(UL connection data) EN 61643-11 2012
Altitude (Dimensions) ≤ 2000 m (operating voltage remote contact ≤ 250 V)
Type (Ambient conditions) DIN rail module, two-section, divisible
Color (Ambient conditions) light grey RAL 7035
SPD Type (Connection data) 4CA
Depth (Key Commercial Data) 74.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 17.7 mm
(Additional technical data) 0.5 A DC (75 V DC)
EN type (Ambient conditions) T3
Height (Key Commercial Data) 93.4 mm
Nominal voltage UN (General) 60 V AC (TN-S)
Combination wave UOC (General) 4 kV
Nominal frequency fN (General) 50 Hz (60 Hz)
Residual current IPE (General) ≤ 5 µA
Shock (operation) (Dimensions) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General) 26 A (at 30 °C)
Response time tA(L-N) (General) ≤ 25 ns
Response time tA(L-PE) (General) ≤ 100 ns
Response time tA(N-PE) (General) ≤ 100 ns
Degree of protection (Dimensions) IP20
Nominal voltage (Connection data) 80 V DC
TOV behavior at UT(L-N) (General) 120 V AC (120 min / withstand mode)
Mounting type (Ambient conditions) DIN rail: 35 mm
TOV behavior at UT(L-PE) (General) 120 V AC (120 min / withstand mode)
Vibration (operation) (Dimensions) 5g (5 ... 500 Hz / 2.5 h / X, Y, Z)
Nominal frequency (Connection data) 50/60 Hz
Mode of protection (Connection data) L-N
Number of ports (Ambient conditions) One
Weight per Piece (excluding packing) 81.160 g
Housing material (Ambient conditions) PA 6.6-FR 20% GF
Operating voltage (UL specifications) 250 V AC (0.5 A)
Reference test voltage UREF (General) 66 V AC
Tightening torque (UL specifications) 5 lbf-in. ... 7 lbf-in.
Horizontal pitch (Key Commercial Data) 1 Div.
Standby power consumption PC (General) ≤ 5.3 mVA (at UREF)
Maximum continuous voltage UC (General) 80 V AC
Mode of protection (Ambient conditions) L-N
Mode of protection (Protective circuit) (DC+) - (DC-)
Rated load current IL (Connection data) 20 A
Degree of pollution (Ambient conditions) 2
Number of positions (Ambient conditions) 2
Screw thread (Additional technical data) M3
Screw thread (Indicator/remote signaling) M3
Voltage protection level Up(L-N) (General) ≤ 0.48 kV
Power distribution system (Connection data) Single phase
Voltage protection level Up(L-PE) (General) ≤ 0.8 kV
Voltage protection level Up(N-PE) (General) ≤ 0.8 kV
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
IEC power supply system (Ambient conditions) TN-S
Short-circuit current rating ISCCR (General) 10 kA AC
Stripping length (Additional technical data) 10 mm
Connection method (Additional technical data) Screw connection
Max. backup fuse with branch wiring (General) 32 A (gG / B / C)
Operating current (Additional technical data) 0.5 A AC
Operating voltage (Additional technical data) 250 V AC
Permissible humidity (operation) (Dimensions) 5 % ... 95 %
Standards/specifications (UL connection data) IEC 61643-11 2011
Stripping length (Indicator/remote signaling) 10 mm
Tightening torque (Additional technical data) 0.5 Nm
Connection method (Indicator/remote signaling) Screw connection
Nominal discharge current In (Connection data) 3 kA
Switching function (Additional technical data) PDT contact
Tightening torque (Indicator/remote signaling) 0.5 Nm
Conductor cross section AWG (UL specifications) 30 ... 12
Maximum backup fuse for through wiring (General) 25 A (gG / B / C)
Nominal discharge current In(8/20) µs (General) 2 kA
Tightening torque (UL indicator/remote signaling) 4.4 lbf-in.
Maximum continuous voltage UC (Protective circuit) 80 V DC
Surge protection fault message (Ambient conditions) Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Measured limiting voltage MLV (L-G) (Connection data) 680 V
Measured limiting voltage MLV (L-N) (Connection data) 490 V
Measured limiting voltage MLV (N-G) (Connection data) 680 V
Conductor cross section AWG (Additional technical data) 30 ... 12
Short-circuit current rating ISCCR (Protective circuit) 0.25 kA DC (without additional backup fuse)
Conductor cross section AWG (Indicator/remote signaling) 24 ... 12
Conductor cross section solid (Additional technical data) 0.2 mm² ... 2.5 mm²
Conductor cross section solid (Indicator/remote signaling) 0.2 mm² ... 4 mm²
Conductor cross section AWG (UL indicator/remote signaling) 16 ... 12
Flammability rating according to UL 94 (Ambient conditions) V-0
Maximum continuous operating voltage MCOV (Connection data) 100 V AC
Conductor cross section flexible (Additional technical data) 0.2 mm² ... 2.5 mm²
Conductor cross section flexible (Indicator/remote signaling) 0.2 mm² ... 2.5 mm²
Maximum discharge current Imax(8/20) µs (Protective circuit) 4 kA

Product Description

Type 3 surge protection, consisting of plug-in protection and base element, with integrated status indicator and remote indication for single-phase power supply networks. Rated Voltage: 60VAC/DC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top