Key Specifications
EAN:: 3471522620118
Customs Tariff Number:: 85364900
Minimum Order Quantity:: 10 piece
Product Net Width: (Ordering): 30 mm
Supplier Information
ABB
ABB
Products: 44170
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
EAN: 3471522620118
Customs Tariff Number: 85364900
Minimum Order Quantity: 10 piece
Product Net Width: (Ordering) 30 mm
Standards: (Technical UL/CSA) IEC 60947-1, IEC 60947-5-1, EN 60947-1, EN 60947-5-1, UL 508, and CSA C22-2 N°14
Product Net Weight: (Ordering) 0.105 kg
Product Name: (Technical UL/CSA) Limit Switch
Actuator Type: (Technical UL/CSA) rotary lever with plastic roller
Package Level 1 EAN: (Dimensions) 3471522620118
Order Multiple: (Technical UL/CSA) 1 piece
Actuation Speed: (Technical UL/CSA) acc. to IEC 60947-5-1 Max. 1.50 m/sacc. to IEC 60947-5-1 Min. 0.06 m/s
Package Level 1 Units: (Dimensions) 1 piece
Package Level 1 Width: (Dimensions) 120 mm
Package Level 2 Units: (Dimensions) 10 piece
Actuation Torque: (Technical UL/CSA) acc. to IEC 60947-5-1 Min. 0.10 N·m
Package Level 1 Height: (Dimensions) 45 mm
Terminal Marking: (Technical UL/CSA) according to EN 50013
Mounting Position: (Technical UL/CSA) all positions are authorised
Product Main Type: (Technical UL/CSA) LS30
Climatic Withstand: (Technical UL/CSA) according to IEC 68-2-3 and salty mist according to IEC 68-2-11
Connecting Capacity: (Technical UL/CSA) AWG 20 ... AWG 140.5 ... 2.5 mm²
Rated Frequency (f): (Technical UL/CSA) Supply Circuit 50 HzSupply Circuit 60 Hz
Degree of Protection: (Technical UL/CSA) acc. to IEC 60529 IP65
Mechanical Durability: (Technical UL/CSA) > 1 million
Package Level 1 Gross Weight: (Dimensions) 0.095 kg
Package Level 2 Gross Weight: (Dimensions) 0.95 kg
Angular Head Adjustment: (Technical UL/CSA) adjustable head every 90°
Movement to be Detected: (Technical UL/CSA) 30° Cam Translation Movement
Angular Lever Adjustment: (Technical UL/CSA) 10° in 10°
Package Level 1 Depth / Length: (Dimensions) 45 mm
Flammability According to UL94: (Environmental) V0
Resistance Between Contacts: (Technical UL/CSA) 25 mΩ
Ambient Air Temperature: (Container Information) Storage -30 ... +80 °COperation -25 ... +70 °C
Rated Insulation Voltage (Ui): (Technical UL/CSA) acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V
Instructions and Manuals: (Additional Information) 1SBC141107C0201
Environmental Information: (Additional Information) 1SBD250112E1000
Number of Auxiliary Contacts NC: (Technical UL/CSA) 1
Number of Auxiliary Contacts NO: (Technical UL/CSA) 1
Mounting by Screws (not supplied): (Technical UL/CSA) 2 x M4 screws
Declaration of Conformity - CE: (Additional Information) 1SBD250881C2000
Rated Operational Current AC-15 (Ie): (Technical UL/CSA) (130 V) 5.5 A(230 V) 3.1 A(240 V) 3 A(24 V) 10 A(400 V) 1.8 A
Rated Operational Current DC-13 (Ie): (Technical UL/CSA) (110 V) 0.6 / 66 A(24 V) 2.8 / 67.2 A(250 V) 0.27 / 67.5 A
ETIM 4: (Certificates and Declarations (Document Number)) EC001829 - Position switch modular
ETIM 5: (Certificates and Declarations (Document Number)) EC001829 - Position switch modular
ETIM 6: (Certificates and Declarations (Document Number)) EC001829 - Position switch modular
UNSPSC: (Certificates and Declarations (Document Number)) 39121500
Maximum Electrical Switching Frequency: (Technical UL/CSA) 3600 cycles per hour
Maximum Mechanical Switching Frequency: (Technical UL/CSA) 600 cycles per hour
Number and Type of Bottom Cable Glands: (Technical UL/CSA) Pg 13,5 cable gland
Pilot Duty of Contact Elements acc. UL508: (Environmental) A600Q600
Rated Impulse Withstand Voltage (Uimp): (Technical UL/CSA) 6 kV
Data Sheet, Technical Information: (Additional Information) 1SBC141107C0201
Conventional Free-air Thermal Current (Ith): (Technical UL/CSA) acc. to IEC 60947-5-1, q = 40 °C 10.0 A
Electrical Shock Protection acc. to IEC 536: (Technical UL/CSA) Double insulation - Class II
Positive Opening Operation of NC Contact(s): (Technical UL/CSA) Yes
Contact Element Form (acc. to IEC 60947-5-1): (Technical UL/CSA) Zb
WEEE Category: (Certificates and Declarations (Document Number)) 5. Small Equipment (No External Dimension More Than 50 cm)
Resistance to Shock acc. to IEC 60068-2-27: (Container Information) Half-sine Pulse for 11 ms, No Change in Contact Position 50 m/s²
Consistency (Measured over 1 Million Operations): (Technical UL/CSA) 0.1 mm
Connecting terminals (delivered in open position): (Technical UL/CSA) M3.5 (+,-) pozidriv 2 screw with cable clamp
Resistance to Vibrations acc. to IEC 60068-2-6: (Container Information) 25g (10 to 500 Hz) no change in position of contacts greater than 100 µs
Positive Opening Operation Torque (Direct Opening Action): (Technical UL/CSA) Minimum Torque acc. to IEC 60947-5-1 0.32 N·m
Action Type of the Contact Element (acc. to IEC 60947-5-1): (Technical UL/CSA) Non-overlapping slow action contacts

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant