Service time: Monday to Friday 9:00-18:00
LIT 2-12 - LIT 2-12 2804694 PHOENIX CONTACT Surge protection device
In Stock Hot Product

LIT 2-12

LIT 2-12 2804694 PHOENIX CONTACT Surge protection device

$0.00 USD
4567 in stock
Key Specifications
GTIN: 4046356462198
Note: Made to Order (non-returnable)
Orderkey: 2804694
(General): Ex iaD 20 T85 °C...T135 °C
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4046356462198
Note Made to Order (non-returnable)
Orderkey 2804694
(General) Ex iaD 20 T85 °C...T135 °C
Catalog page Page 92 (C-6-2013)
Packing unit 10 pc
ATEX (General)  II 1 G Ex ia IIC T4...T6
IECEx (General) Ga Ex ia IIC T4...T6
Country of origin DE (Germany)
Capacity (General) ≤ 1.5 nF (per path)
Custom tariff number 85363010
Altitude (Dimensions) ≤ 2000 m (amsl (above mean sea level))
Rated current (General) 500 mA (40 °C)
(Conformity / approvals) For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Type (Ambient conditions) DIN rail module, one-piece
Color (Ambient conditions) anthracite grey RAL 7016
Depth (Key Commercial Data) 102.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data) 6.2 mm
(Standards and Regulations) 500 mA (T6 / ≤ 40 °C)
Height (Key Commercial Data) 93.1 mm
Nominal voltage UN (General) 12 V DC
Residual current IPE (General) ≤ 2 µA
Resistance in series (General) 0 Ω
Degree of protection (Dimensions) IP20
IEC test classification (General) C1
Screw thread (Protective circuit) M3
Mounting type (Ambient conditions) DIN rail: 35 mm
China RoHS (Conformity / approvals) Environmentally Friendly Use Period = 50
Connection method (Connection data) DIN rail NS35
(Connection, equipotential bonding) IEC 60079-26 2006
Input attenuation aE, sym. (General) typ. 0.3 dB (1.5 MHz/50 Ω)
Max. required back-up fuse (General) 500 mA (T)
Weight per Piece (excluding packing) 55.750 g
Housing material (Ambient conditions) PBT
Response time tA(line-line) (General) ≤ 1 ns
Stripping length (Protective circuit) 8 mm
Connection method (Protective circuit) Screw connection
Response time tA(line-earth) (General) ≤ 100 ns
Tightening torque (Protective circuit) 0.8 Nm
Maximum continuous voltage UC (General) 18 V DC
Direction of action (Ambient conditions) Line-Line & Line-Earth Ground
Impulse durability (line-line) (General) C1 - 500 V / 250 A
Surge protection fault message (General) none
Impulse durability (line-earth) (General) C1 - 500 V / 250 A
Residual voltage at In(line-line) (General) ≤ 50 V
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
Operating effective current ICat UC (General) ≤ 2 µA
max. input power Pi (Standards and Regulations) 635 mW
Conductor cross section AWG (Protective circuit) 24 ... 14
Voltage protection level Up(line-line) (General) ≤ 50 V (C1 - 500 V / 250 A)
Max. input current Ii (Standards and Regulations) 500 mA (T4 / ≤ 80°C)
Max. input voltage Ui (Standards and Regulations) 18 V DC
Voltage protection level Up(line-earth) (General) ≤ 650 V (C1 - 500 V / 250 A)
Conductor cross section solid (Protective circuit) 0.2 mm² ... 2.5 mm²
Total discharge current Itotal(8/20) µs (General) 10 kA
Ambient temperature (storage/transport) (Dimensions) -40 °C ... 80 °C
Conductor cross section flexible (Protective circuit) 0.2 mm² ... 2.5 mm²
Max. internal inductance Li (Standards and Regulations) < 1 µH
Maximum inner capacitance Ci (Standards and Regulations) typ. 3 nF
Flammability rating according to UL 94 (Ambient conditions) V-0
Alternating current carrying capacity (line-earth) (General) 5 A - 1 s
Cut-off frequency fg (3 dB), sym. in 50 Ohm system (General) typ. 5 MHz
Nominal discharge current In(8/20) µs (line-line) (General) 350 A
Standards/specifications (Connection, equipotential bonding) EN 61643-21 A2:2013
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General) typ. 1.7 MHz
Maximum inner time factor (Ri/Li) (Standards and Regulations) 10 µs
Nominal discharge current In(8/20) µs (line-earth) (General) 5 kA
Nominal pulse current Ian (10/1000) µs (line-line) (General) 70 A
Residual voltage with Ian (10/1000) µs (line-line) (General) ≤ 50 V
Nominal pulse current Ian (10/1000) µs (line-earth) (General) 50 A
Pulse discharge current Iimp(10/350) µs (line-earth) (General) 500 A
Output voltage limitation at 1 kV/µs (line-line) spike (General) ≤ 50 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 650 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General) 350 A
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 10 kA

Product Description

Surge protection on the module for one-piece symmetrical rail mounting, 6.2 mm wide, for two potential-free signal conductors. Tested according to the degrees of protection in the Ex zones: Ex ia IIC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top