Service time: Monday to Friday 9:00-18:00
K8AC-CT200L - K8AC-CT200L K8AC0016D 184037 OMRON Current Transformer for K8AB-AS3
In Stock Hot Product

K8AC-CT200L

K8AC-CT200L K8AC0016D 184037 OMRON Current Transformer for K8AB-AS3

$0.00 USD
3494 in stock
Key Specifications
: 10 to 100 A AC, 20 to 200 A AC
EMC: EN 60947-5-1
Weight: Approx. 150 g
K8AK-AW3: AC input (45 to 65 Hz)
Supplier Information
OMRON
OMRON
Products: 41472
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
10 to 100 A AC, 20 to 200 A AC
EMC EN 60947-5-1
Weight Approx. 150 g
K8AK-AW3 AC input (45 to 65 Hz)
Indicators Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM): Red LED
Operate (SV) Operating value setting range
Repeat error Operating value
Reset (HYS.) Hysteresis
Case material PC and ABS
100 to 240 VAC K8AK-AW1 100-240 VAC
Operating time ±50 ms (at 25°C and 65% humidity, rated power supply voltage)
Electrical life 50,000 operations at 5 A, 250 VAC or 30 VDC
Mechanical life 10,000,000 operations
Operating power Isolated power supply
Operating value 100% operation at set value
Resetting method Manual reset/automatic reset (switchable)Manual reset: Turn OFF operating power for 1 s or longer
Safety standards UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA and CCC
Measuring current Supply voltage
Overload capacity K8AK-AW1/-AW2
Operating time (T) 0.1 to 30 s
Current transformer Input range
Storage temperature -25 to 65°C (with no condensation or icing)
Applicable standards Conforming standards
Degree of protection Terminal section: IP20
Input frequency range K8AK-AW1/-AW2
Maximum contact current 5 A
Maximum contact voltage 250 VAC or 30 VDC
Operating voltage range 85% to 110% of rated operating voltage
Size in mm (H × W × D) 90 × 22.5 × 100
Maximum switching capacity 1,250 VA, 150 W
Rated power supply frequency 50/60 Hz±5 Hz (AC power supply)
10 to 100 A AC,20 to 200 A AC 24 VAC/DC
Ambient operating temperature -20 to 60°C (with no condensation or icing)
Operating power ON lock (LOCK) 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.)Note: Enabled only for overcurrent operation
0.1 to 1 A AC/DC,0.5 to 5 A AC/DC 24 VAC/DC
Output relays(1 × SPDT, normally closed operation) Resistive load
2 to 20 mA AC/DC,10 to 100 mA AC/DC,50 to 500 mA AC/DC 24 VAC/DC

Product Description

Current transformer for monitoring relays, high current monitoring capacity
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

These single-phase current relays monitor over- and undercurrents. Manual resetting and automatic resetting are supported by one relay. The start-up lock and operating time can be set separately. The relay warning status is easily monitored with the LED indicator.

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top