Key Specifications
GTIN: 4055626765778
Orderkey: 1072838
(General): Ethernet/Ethernet 500 V AC 50 Hz 1 min.
Catalog page: Page 163 (C-6-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4055626765778
Orderkey 1072838
(General) Ethernet/Ethernet 500 V AC 50 Hz 1 min.
Catalog page Page 163 (C-6-2019)
Depth (Note) 99 mm
Packing unit 1 pc
Width (Note) 45 mm
(Interfaces) Short-circuit protection for the sensor supply
Height (Note) 114.5 mm
(Digital inputs) Short-circuit protection for the sensor supply
(IO-Link inputs) Short-circuit protection
Country of origin US (United States)
ETIM 5.0 (eCl@ss) EC001604
ETIM 6.0 (eCl@ss) EC001604
ETIM 7.0 (eCl@ss) EC001604
(Digital outputs) max. 200 mA (at L+/L-)
Custom tariff number 85176200
Test section (General) 24 V supply/Ethernet 500 V AC 50 Hz 1 min.
(Electrical isolation) pass
Input name (Interfaces) Digital inputs
Input frequency (Interfaces) 0.5 kHz
eCl@ss 8.0 (Classifications) 27242608
eCl@ss 9.0 (Classifications) 27242608
Number of inputs (Interfaces) max. 8 (EN 61131-2 types 1 and 3)
Connection method (Interfaces) Push-in / plug connection
Protective circuit (Interfaces) Overload protection
Type of protection (Interfaces) Overload protection
Designation (Ambient conditions) PROFINET
Number of ports (Digital inputs) 8
Degree of protection (Dimensions) IP20
Total sensor current (Interfaces) max. 1.6 A (from L+/L-)
Connection method (Digital inputs) Push-in / plug connection
Connection method (IO-Link inputs) Push-in / plug connection
Connection technology (Interfaces) 3-wire
Number of outputs (IO-Link inputs) max. 8
Color (Supply of the IO-Link ports) gray
Output description (IO-Link inputs) IO-Link ports in digital output (DO) mode
Type of protection (Digital inputs) Overload protection
Type of protection (IO-Link inputs) Overload protection
No. of channels (Ambient conditions) 2
Nominal load, ohmic (IO-Link inputs) 4.8 W (120 Ω, at nominal load)
Type of protection (Digital outputs) Overload protection
Weight per Piece (excluding packing) 0.010 g
Description of the input (Interfaces) IO-Link ports in digital input (DI) mode
Total sensor current (Digital inputs) max. 1.6 A (from L+/L-)
Connection method (Ambient conditions) RJ45 socket
Connection technology (Digital inputs) 3-wire
Connection technology (IO-Link inputs) 3-wire
Nominal input current (Digital inputs) typ. 3.5 mA
Nominal input voltage UIN (Interfaces) 24 V DC
Behavior with overload (IO-Link inputs) Shutdown with automatic restart
Mechanical tests (Electrical isolation) Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 1g
Nominal output voltage (IO-Link inputs) 24 V DC
Sensor current per channel (Interfaces) max. 200 mA (from L+/L-)
Transmission speed (Ambient conditions) 10/100 Mbps (with auto negotiation)
Net weight (Supply of the IO-Link ports) 366.7 g
Description of the input (Digital inputs) Digital inputs (DI)
Nominal input current at UIN (Interfaces) typ. 3.5 mA
Transmission physics (Ambient conditions) Ethernet in RJ45 twisted pair
Nominal input voltage UIN (Digital inputs) 24 V DC
Permissible cable length (Digital outputs) < 20 m
Input voltage range "0" signal (Interfaces) 8 V DC ... 11.5 V DC (for C/Q pin)
Input voltage range "1" signal (Interfaces) 10.5 V DC ... 13 V DC
Mounting type (Supply of the IO-Link ports) DIN rail
Sensor current per channel (Digital inputs) max. 200 mA (from L+/L-)
Ambient temperature (operation) (Dimensions) -25 °C ... 60 °C
Permissible humidity (operation) (Dimensions) 10 % ... 95 %
Utilization restriction (Key Commercial Data) EMC: class A product, see manufacturer's declaration in the download area
Housing material (Supply of the IO-Link ports) Polyamide
Input voltage range "0" signal (Digital inputs) 5.2 V DC ... 6.4 V DC
Input voltage range "1" signal (Digital inputs) 6.8 V DC ... 8 V DC
Nominal voltage for I/O supply (Digital outputs) 24 V DC
Output current when switched off (IO-Link inputs) max. 400 µA
Output voltage when switched off (IO-Link inputs) max. 1 V
Maximum output current per device (IO-Link inputs) 1.6 A
Maximum output current per channel (IO-Link inputs) 200 mA
Ambient temperature (storage/transport) (Dimensions) -25 °C ... 85 °C
Permissible humidity (storage/transport) (Dimensions) 10 % ... 95 %
Nominal current for every IO-Link port (Digital outputs) max. 200 mA (at C/Q)

Product Description

The eight-channel IO-Link master offers convenient configuration of IO-Link devices via web-based management. It enables connectivity with PROFINET IO, MODBUS and OPC UA networks. It has eight additio
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top