Key Specifications
: max. 32768 Bit (internal Modbus Client)
Depth: 71.5 mm
Shock: 25g, Criterion 1, according to IEC 60068-2-27
Width: 80 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
max. 32768 Bit (internal Modbus Client)
Depth 71.5 mm
Shock 25g, Criterion 1, according to IEC 60068-2-27
Width 80 mm
Height 119.8 mm
Weight 285 g
Interface INTERBUS local bus (master)
Input name Digital inputs
Output name Digital outputs
Mass storage 1 Mbyte
Program memory 1 Mbyte (86 K instructions (IL))
Realtime clock Yes
Supply voltage 24 V DC
Device function PROFINET device
Residual ripple ± 5 %
Diagnostics tool DIAG+
Number of inputs 8
Programming tool PC WORX / PC WORX EXPRESS
Connection method Inline data jumper
Number of outputs 4
Power dissipation max. 5 W
Configuration tool Config+ Version 1.01 or later
Transmission speed 500 kBaud / 2 MBaud (can be switched)
Diagnostics display No
Degree of protection IP20
Supply voltage range 19.2 V DC ... 30 V DC
Without analog input yes
Controller redundancy No
Vibration (operation) 5g
Without analog output yes
Without counter input yes
Amount of process data max. 4096 Bit (INTERBUS)
Retentive mass storage 48 kByte (NVRAM)
Number of control tasks 8
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Description of the input EN 61131-2 type 1 NPN/PNP
Max. current consumption 870 mA (370 mA communications power + 500 mA analog voltage supply)
Number of supported devices max. 128
Typical current consumption 210 mA
Without pulse direction output yes
Ambient temperature (operation) -25 °C ... 55 °C
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
Maximum output current per channel 500 mA
Ambient temperature (storage/transport) -25 °C ... 85 °C
Number of devices with parameter channel max. 24
Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
Number of local bus devices that can be connected max. 63 (observe current consumption)
Number of supported branch terminals with remote bus branch max. 3

Product Description

The Inline controller offers the possibility of communicating via PROFINET and Modbus/TCP. Programming is done with PC Worx Express or PC Worx (IEC 61131-3).
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

The ILC 191 ETH 2TX modular small-scale controller for the Inline I/O system is at the heart of Easy Automation. The ILC 1X1 series is characterized by its support for the Modbus/TCP and PROFINET Ethernet-based protocols. A new feature is the support for an optional SD card.