Key Specifications
: Failure of or insufficient communications power ULI/O error message sent to the bus coupler
Type: modular
Depth: 71.5 mm
Width: 12.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Failure of or insufficient communications power ULI/O error message sent to the bus coupler
Type modular
Depth 71.5 mm
Width 12.2 mm
Height 136.8 mm
CCCex note Use in potentially explosive areas is not permitted in China.
Input name Analog UTH inputs
Current draw max. 60 mA
Product type I/O component
ID code (hex) 7F
Mounting type DIN rail mounting
ID code (dec.) 127
Operating mode Process data operation with 2 words
Product family Inline
Supply voltage 7.5 V DC (via voltage jumper)
Connection name Inline connector
Register length 32 bit
Article revision 11
Number of inputs 2 (Thermocouples or linear voltage)
Pollution degree 2 (IEC 60664-1, EN 60664-1)
Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Stripping length 8 mm
Connection method Inline data jumper
Length code (dec) 02
Length code (hex) 02
Scope of delivery including Inline connector and labeling field
Input address area 4 Byte
Note on dimensions Housing dimensions
Protective circuit Surge protection (TC channels); up to ±40 V
Transmission speed 500 kbps
A/D conversion time typ. 120 µs (per channel)
Dimensional drawing
Measuring principle Successive approximation
Note on application Only for industrial use
Output address area 4 Byte
Process data update max. 30 ms (For both channels)
Degree of protection IP20
Diagnostics messages Failure of the internal I/O supply I/O error message sent to the bus coupler
Number of interfaces 2
Overvoltage category II (IEC 60664-1, EN 60664-1)
Process data channel 32 bit
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Connection technology 2-conductor
Required parameter data 6 Byte
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Description of the input Inputs for thermocouples or linear voltage
Conductor cross section AWG 28 ... 16
Required configuration data 4 Byte
Conductor cross section rigid 0.08 mm² ... 1.5 mm²
Measured value representation 16 bits (15 bits + sign bit)
Conductor cross section, rigid 0.08 mm² ... 1.5 mm²
Ambient temperature (operation) -25 °C ... 55 °C
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section flexible 0.08 mm² ... 1.5 mm²
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Conductor cross section, flexible 0.08 mm² ... 1.5 mm²
Sensor types that can be used (TC) U, T, L, J, E, K, N, S, R, B, C, W, HK
Ambient temperature (storage/transport) -25 °C ... 85 °C
Note regarding the connection technology Shielded compensating line for TC with encapsulated sensors
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Maximum power dissipation for nominal condition 0.9 W
Test voltage: 7.5 V supply (bus logic)/functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V analog supply (analog I/O)/functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC, 50 Hz, 1 min.

Product Description

Inline, Temperature recording module, Analogue UTH inputs: 2 (Thermocouples or linear voltage), connection technology: 2 conductors, transmission rate on local bus: 500 kBit/s, protection rating: IP20
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top