Service time: Monday to Friday 9:00-18:00
IB IL AO 1/SF-PAC - IB IL AO 1/SF-PAC 2861315 PHOENIX CONTACT Inline terminal
In Stock Hot Product

IB IL AO 1/SF-PAC

IB IL AO 1/SF-PAC 2861315 PHOENIX CONTACT Inline terminal

$0.00 USD
4160 in stock
Key Specifications
: 4 mA ... 20 mA
Type: modular
Depth: 71.5 mm
Width: 24.4 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
4 mA ... 20 mA
Type modular
Depth 71.5 mm
Width 24.4 mm
Height 135 mm
CCCex note Use in potentially explosive areas is not permitted in China.
Output name Analog output
Current draw max. 40 mA
Product type I/O component
ID code (hex) 7D
Mounting type DIN rail mounting
DAC resolution 16 bit
ID code (dec.) 125
Operating mode Process data mode with one word
Product family Inline
Supply voltage 7.5 V DC (via voltage jumper)
Connection name Inline connector
Register length 16 bit
Article revision 20
Pollution degree 2 (IEC 60664-1, EN 60664-1)
Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Stripping length 8 mm
Connection method Inline data jumper
Length code (dec) 01
Length code (hex) 01
Number of outputs 1
Scope of delivery including Inline connectors and marking fields
Input address area 0 Byte
Note on dimensions Housing dimensions
Protective circuit Transient protection of outputs
Transmission speed 500 kbps
Dimensional drawing
Note on application Only for industrial use
Output address area 2 Byte
Process data update < 1 ms
Degree of protection IP20
Diagnostics messages Failure of or insufficient communications power ULI/O error message sent to the bus coupler
Number of interfaces 2
Overvoltage category II (IEC 60664-1, EN 60664-1)
Process data channel 16 bit
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Connection technology 2-conductor
Current output signal 0 mA ... 20 mA
Voltage output signal 0 V ... 10 V
Required parameter data 4 Byte
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
D/A converter resolution 16 bit
Conductor cross section AWG 28 ... 16
Required configuration data 4 Byte
Conductor cross section rigid 0.08 mm² ... 1.5 mm²
Conductor cross section, rigid 0.08 mm² ... 1.5 mm²
Ambient temperature (operation) -25 °C ... 55 °C
Load/output load current output < 500 Ω
Load/output load voltage output > 2 kΩ
Representation of output values 16-bit straight binary
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section flexible 0.08 mm² ... 1.5 mm²
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Conductor cross section, flexible 0.08 mm² ... 1.5 mm²
Test voltage: I/O/functional ground 500 V AC, 50 Hz, 1 min.
Ambient temperature (storage/transport) -25 °C ... 85 °C
Note regarding the connection technology shielded
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Maximum power dissipation for nominal condition 1.85 W
Test voltage: 7.5 V supply (bus logic), 24 V supply UANA/ I/O 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic), 24 V supply UANA/ functional ground 500 V AC, 50 Hz, 1 min.

Product Description

Inline, Analog output terminal, Analog output: 1, 0 V ... 10 V, 0 mA... 20 mA, 4 mA... 20 mA, connection technology: 2 conductors, transmission rate on the local bus: 500 kBit/s, protection rating: IP
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top