Service time: Monday to Friday 9:00-18:00
FM-213-4 - FM-213-4 PANASONIC flow sensor FM200, 1000ml/min,ø4, NPN
In Stock Hot Product

FM-213-4

FM-213-4 PANASONIC flow sensor FM200, 1000ml/min,ø4, NPN

$0.00 USD
3922 in stock
Key Specifications
Item: Specifications
Weight: Net weight: 50 g approx., Gross weight: 115 g approx.
Details: Resin body type
Display: 4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
Item Specifications
Weight Net weight: 50 g approx., Gross weight: 115 g approx.
Details Resin body type
Display 4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Product Integrated Display Type Digital Flow Sensor
Material Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber
Linearity Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side)
Port size ø4 ø0.157 push-in
Protection IP40 (IEC)
Accessories CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc.
Part Number FM-213-4
Cable length Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable.
Product name Integrated Display Type Digital Flow Sensor FM-200
Repeatability Within ±1 % F.S.
External input ON voltage: 0 to +0.4 VOFF voltage: +5 V to +V, or openInput time: 80 ms or more
Product Number FM-213-4
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P10 % or less
Ambient humidity 35 to 90 % RH, Storage: 35 to 90 % RH
Applicable fluid Clean air, compressed air, nitrogen gas(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2.
Shock resistance 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each
Connecting method Connector
Comparative output NPN open-collector transistor・Maximum sink current: 50 mA or less・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)・Residual voltage: 2.4 V or less (at 50 mA sink current)
Enclosure earthing Floating(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor.
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉
Current consumption Normal mode: 60 mA or less, ECO mode: 40 mA or less
Full scale flow rate 1,000 mℓ/min.(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa).
Rated pressure range -0.09 to +0.7 MPa
Vibration resistance 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or 49 m/s2max. acceleration, in X, Y and Z directions for two hours each
Analog voltage output Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.[Refer to "Analog voltage output" for more details.]
Insulation resistance 10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type)
Accuracy assurance range Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.One-side direction : +3 to +100 % F.S.(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted.
Pressure characteristics Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side)
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type)
Pressure withstandability 1 MPa
Specified integrated value 10 mℓ
Temperature characteristics Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range)
Comparative output:Hysteresis Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit)
CE marking directive compliance EMC Directive, RoHS Directive
Comparative output:Output modes Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode
Instant flow rate:Display range -1,100 to +1,100 mℓ/min.(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
Comparative output:Response time 50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation
Integrated flow rate:Display range ±9999999 mℓ(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.).
Comparative output:Short-circuit protection Incorporated
Instant flow rate:Setting and display resolution 1 mℓ/min.
Integrated flow rate:Setting and display resolution 1 mℓ

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top