Key Specifications
: SPD according to AS/NZS 1768 Cat. C3
Note: Max. single impulse: 100 kA (8/20 µs)
Type: DIN rail module, two-section, divisible
Depth: 74.5 mm (incl. DIN rail 7.5 mm)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
SPD according to AS/NZS 1768 Cat. C3
Note Max. single impulse: 100 kA (8/20 µs)
Type DIN rail module, two-section, divisible
Depth 74.5 mm (incl. DIN rail 7.5 mm)
Width 142.4 mm
Height 95.2 mm
EN type T1 / T2
Altitude ≤ 2000 m (amsl)
SPD Type 2CA
Product type Combination type
Screw thread M5
Mounting type DIN rail: 35 mm
Material group I
Product family SEC Family
Connection name Remote fault indicator contact
Nominal voltage 240/415 V AC
Open side panel No
Article revision 13
Horizontal pitch 8 Div.
Housing material PA 6.6-FR 20 % GF
Pollution degree 2
Response time tA ≤ 100 ns
Stripping length 18 mm
Connection method Screw connection
Nominal frequency 50/60 Hz
Operating current 10 mA AC ... 1 A AC
Operating voltage 12 V AC ... 250 V AC
Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque 4.5 Nm
Mode of protection L-N
Nominal voltage UN 240/415 V AC (TN-S)
Switching function Changeover contact
Dimensional drawing
Direction of action 3L-N & N-PE
Insulating material PA6.6-FR 20% GF
Number of positions 4
AC operating current 1 A AC
Color (Base element) gray (RAL 7042)
Degree of protection IP20 (only when all terminal points are used)
Nominal frequency fN 50 Hz (60 Hz)
Overvoltage category III
Residual current IPE ≤ 0.01 mA
CTI value of material 600
Rated load current IL 125 A (< 55 °C)
Vibration (operation) 5g (5 - 500 Hz/2.5 h/X, Y, Z)
Color (Male connector) light gray (RAL 7035)
IEC power supply system TN-S
IEC test classification I / II
TOV behavior at UT(L-N) 415 V AC (5 s / withstand mode)
Standards/specifications IEC 61643-11
TOV behavior at UT(N-PE) 1200 V AC (200 ms / withstand mode)
Power distribution system Wye
Residual voltage Ures(L-N) ≤ 1.5 kV (at In)
Conductor cross section AWG 13 ... 2
Residual voltage Ures(L-PE) ≤ 2.5 kV (at In)
Residual voltage Ures(N-PE) ≤ 1.5 kV (at In)
Nominal discharge current In 20 kA
Conductor cross section rigid 2.5 mm² ... 35 mm²
Maximum continuous voltage UC 350 V AC
Surge protection fault message Optical, remote indicator contact
Ambient temperature (operation) -40 °C ... 80 °C
Conductor cross section flexible 2.5 mm² ... 35 mm²
Permissible humidity (operation) 5 % ... 95 %
Voltage protection level Up(L-N) ≤ 1.5 kV
Voltage protection level Up(L-PE) ≤ 2.5 kV
Voltage protection level Up(N-PE) ≤ 1.5 kV
Short-circuit current rating ISCCR 50 kA
Max. backup fuse with branch wiring 315 A (gG)
Short-circuit current rating (SCCR) 50 kA
Voltage protection rating VPR (L-G) 1500 V
Voltage protection rating VPR (L-L) 2000 V
Voltage protection rating VPR (L-N) 1500 V
Voltage protection rating VPR (N-G) 1200 V
Flammability rating according to UL 94 V-0
Ambient temperature (storage/transport) -40 °C ... 80 °C
Follow current interrupt rating Ifi(N-PE) 100 A
Follow current quenching capacity Ifi(L-N) 50 kA
Max. backup fuse with V-type through wiring 125 A (gG)
Total discharge current Itotal(10/350) µs 100 kA
Nominal discharge current In(8/20) µs (L-N) 25 kA
Nominal discharge current In(8/20) µs (L-PE) 25 kA
Nominal discharge current In(8/20) µs (N-PE) 100 kA
Maximum discharge current Imax(8/20) µs (L-N) 50 kA
Maximum continuous operating voltage MCOV (L-G) 350 V AC
Maximum continuous operating voltage MCOV (L-L) 700 V AC
Maximum continuous operating voltage MCOV (L-N) 350 V AC
Maximum continuous operating voltage MCOV (N-G) 350 V AC
Maximum discharge current Imax(8/20) µs (L-PE) 50 kA
Impulse discharge current (10/350) µs (L-PE), charge 12.5 As
Impulse discharge current (10/350) µs (N-PE), charge 50 As
Impulse discharge current (10/350) µs (L-N), charge 12.5 As
Impulse discharge current (10/350) µs (L-N), specific energy 160 kJ/Ω
Impulse discharge current (10/350) µs (N-PE), specific energy 2500 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), specific energy 160 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp 25 kA
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp 100 kA
Impulse discharge current (10/350) µs (L-N), peak current value Iimp 25 kA

Product Description

Plug-in lightning current arrester according to type 1/class I, for three-phase power grids with separate N and PE (L1, L2, L3, PE, N).
Key Features
  • Industrial grade quality
  • RoHS compliant