Key Specifications
: -0.5 V DC ... 5 V DC (“0” signal)
LTE: CAT1, CAT4
EDGE: Multislot Class 10
GPRS: Class 12, Class B
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
-0.5 V DC ... 5 V DC (“0” signal)
LTE CAT1, CAT4
EDGE Multislot Class 10
GPRS Class 12, Class B
Note Hardware revision 02 or later
Type in housing
UMTS HSPA 3GPP R6
Depth 70.00 mm
Width 285.00 mm
Height 158.00 mm
Antenna max. cable length of 30 m
Battery integrated (rechargeable battery buffered)
Voltage ± 12 V
EMC note EMC: class A product, see manufacturer's declaration in the download area
Frequency 900 MHz (GSM/GPRS/EDGE )
Impedance 50 Ω
Interface Ethernet (2x)
Proximity Analog input, reserved for future applications
Application Programmable charging controller for DC and AC charging of electric vehicles in accordance with IEC 61851-1,-23, DIN SPEC 70121, and CHAdeMO, with integrated cellular modem
Output name AC charging locking system
Cable length max. 30 m
Product type DC charging controller
Relay output DC charging enabled
Assembly note DIN rail mounting
Charging mode Mode 4
Communication DIN SPEC 70121
Mounting type DIN rail mounting
SIM Interface 1.8 volt and 3 volt SIM card
Number outputs 16
Operating mode Stand-Alone
Output voltage 24 V DC
Product family CHARX control professional
Program memory 1 Mbyte (86 K instructions (IL))
Realtime clock yes
Runtime system eCLR
Supply voltage 24 V DC (Length of cable max. 30 m)
Activation time Can be set via application program
Locking control Relay output, supplied internally
Article revision 06
Diagnostics tool DIAG+
Engineering tool PC Worx
Locking feedback Resistance measurement
Processing speed 1.3 ms (1 K mix instructions)
Connection method COMBICON connectors
Mounting position horizontal
Shock (operation) 25g (Criterion 1, according to IEC 60068-2-27)
Supply voltage UL 24 V DC
Temperature range -20 °C ... 120 °C
Power supply at UL max. 0.8 A DC
Power supply at UM max. 8 A DC (sum of UM+ US)
Power supply at US max. 8 A DC (sum of UM+ US)
Transmission speed 100 Mbps
Data storage system 1 Mbyte
Input voltage range -0.5 V DC ... 30 V DC
Protocols supported OCPP 1.6J (Core-Profile)
Temperature sensors 2x Pt 1000
Transmission length max. 3 m (with shielded cable max. 30 m)
Configuration memory min. 4 Mbyte (depending on storage media)
Degree of protection IP20
Number of interfaces 2
Supply voltage range 19.2 V DC ... 30 V DC (Incl. all tolerances, incl. residual ripple)
Switching thresholds Can be set via application program
Termination resistor 120 Ω (Can be connected internally)
Interface description 3G / 2G
Standards/regulations IEC 61851-1
Typical response time min. 3 ms
Vibration (operation) 5g
Max. switching current 6 A (External supply)
Maximum output current max. 2 A
Maximum output voltage 12 V DC (Internal supply)
Retentive data storage 48 kByte (NVRAM)
Number of control tasks 8
Supply voltage range UM 24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Description of the input EN 61131-2 type 1
Number of digital inputs 16
Maximum switching voltage 30 V (External supply)
Number of charging points 2
Segment circuit supply US 24 V DC -15 % / +20 % (in accordance with EN 61131-2)
Conductor cross section AWG 28 ... 16
Current consumption from UM max. 8 A DC
Current consumption from US max. 8 A DC
Conductor cross section rigid 0.08 mm² ... 1.5 mm²
Vibration (storage/transport) 5g
Ambient temperature (operation) -25 °C ... 55 °C
Conformance with EMC directives Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN 61000-4-2/IEC 61000-4-2 Criterion B, ±4 kV contact discharge, ±8 kV air discharge
Air pressure (storage/transport) 58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Conductor cross section flexible 0.08 mm² ... 1.5 mm²
Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
Maximum output current per channel 500 mA
Behavior in the event of voltage drop Automatic unlocking
Maximum current for locking actuators 2 A
Ambient temperature (storage/transport) -40 °C ... 85 °C
Resistance to permanent reverse voltage max. 500 mA
Permissible humidity (storage/transport) 10 % ... 95 % (in accordance with EN 61131-2)
Residual ripple, in reference to the measured value 5 %

Product Description

Programmable load control for DC and AC charging of electric vehicles according to IEC 61851-1,-23, DIN SPEC 70121, CHAdeMO with integrated mobile radio modem
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty