Service time: Monday to Friday 9:00-18:00
DT-TELE-SHDSL - DT-TELE-SHDSL 2801593 PHOENIX CONTACT Surge protection device
In Stock Hot Product

DT-TELE-SHDSL

DT-TELE-SHDSL 2801593 PHOENIX CONTACT Surge protection device

$0.00 USD
3883 in stock
Key Specifications
: C1
Note: 2002
Type: Attachment plug for DIN rail mounting
Color: silver-colored
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
C1
Note 2002
Type Attachment plug for DIN rail mounting
Color silver-colored
Depth 63 mm
Width 25 mm
Height 103 mm
Product type Surge protection for information technology
Screw thread M2
Mounting type Connection-specific attachment plug and DIN rail, 35 mm
Rated current ≤ 380 mA (25 °C)
Product family DATATRAB
Open side panel No
Article revision 07
Housing material Zinc die-cast
Connection method RJ45 / COMBICON
Tightening torque 0.22 Nm
Dimensional drawing
Direction of action Line-Line & Line-Ground/Shield
Number of positions 4
Resistance per path 3.3 Ω 20 %
Capacity (Core-Core) 55 pF
Degree of protection IP20
Residual current IPE ≤ 4 µA
Capacity (Core-Earth) 7 pF
Standards/regulations IEC 60664-1 / VDE 0110-1
VDE requirement class B2
Wire pairs per module 2
IEC test classification B2
Standards/specifications IEC 61643-21
Input attenuation aE, sym. typ. 0.3 dB (≤ 2,8 MHz / 100 Ω)
Conductor cross section AWG 28 ... 16
Response time tA(line-line) ≤ 100 ns
Response time tA(line-earth) ≤ 100 ns
Conductor cross section rigid 0.14 mm² ... 1.5 mm²
Maximum continuous voltage UC 185 V DC
Impulse durability (line-line) C1 - 1 kV / 500 A
Surge protection fault message none
Ambient temperature (operation) -40 °C ... 85 °C
Impulse durability (line-earth) B2 - 4 kV / 100 A
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
Operating effective current ICat UC ≤ 6 µA
Voltage protection level Up(line-line) 250 V (B2 - 100 A)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Voltage protection level Up(line-earth) ≤ 580 V (B2 - 100 A)
Pulse discharge current Iimp(10/350) µs 2.5 kA (Number of pulses category D1)
Total discharge current Itotal(8/20) µs 10 kA
Nominal discharge current In(8/20) µs (line-line) ≤ 5 kA
Nominal pulse current Ian (10/700) µs (line-line) 150 A
Nominal pulse current Ian (10/1000) µs (line-line) 100 A
Nominal pulse current Ian (10/700) µs (line-earth) 150 A
Cut-off frequency fg (3 dB), sym. in 100 Ω system 25 MHz
Nominal discharge current In(8/20) µs (line-ground) ≤ 5 kA
Nominal pulse current Ian (10/1000) µs (line-earth) 100 A

Product Description

Intermediate part with surge protection for two SHDSL telecommunication interfaces (ports). Connection: RJ45 (RJ12/RJ11) and plug-in screw terminal. Alternatively, it can be fitted on a rail.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top