Service time: Monday to Friday 9:00-18:00
CN-UB-280DC-3-BB - CN-UB-280DC-3-BB 2801050 PHOENIX CONTACT Surge protection device
In Stock Hot Product

CN-UB-280DC-3-BB

CN-UB-280DC-3-BB 2801050 PHOENIX CONTACT Surge protection device

$0.00 USD
3303 in stock
Key Specifications
GTIN: 4046356675727
Orderkey: 2801050
(General): D1 - 2.5 kA
Catalog page: Page 176 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

Parameter Value
GTIN 4046356675727
Orderkey 2801050
(General) D1 - 2.5 kA
Catalog page Page 176 (C-4-2017)
Packing unit 1 pc
(Dimensions) IP55
Country of origin CN (China)
(Connection data) EN 61643-21/A1 2009
Custom tariff number 85363010
Altitude (Dimensions) 2000 m
Rated current (General) 5 A (25 °C)
Frequency range (General) 0 Hz ... 3 GHz
Type (Ambient conditions) Attachment plug
Color (Ambient conditions) nickel
Width (Key Commercial Data) 31 mm
Height (Key Commercial Data) 33.5 mm
Length (Key Commercial Data) 57.8 mm
Capacity (line-earth) (General) typ. 1.5 pF
Degree of protection (Dimensions) IP55
IEC test classification (General) C2
Mounting type (Ambient conditions) Connection-specific intermediate plugging
Weight per Piece (excluding packing) 145.000 g
Housing material (Ambient conditions) HPb59-1
Input attenuation aE, asym. (General) typ. 0.1 dB (≤ 3 GHz)
Connection method (Protective circuit) N connector 50 Ω
Response time tA(line-earth) (General) ≤ 100 ns
Maximum continuous voltage UC (General) 280 V DC
Capacity asymmetrical (shield) (General) typ. 1.5 pF
Direction of action (Ambient conditions) Line-Shield/Earth Ground
Number of positions (Ambient conditions) 1
Response time tA (line-shield) (General) ≤ 100 ns
Surge protection fault message (General) none
Connection method IN (Protective circuit) N connector, female
Impulse durability (line-earth) (General) C2 - 10 kV/5 kA
Connection method OUT (Protective circuit) N connector, female
Standards/specifications (Connection data) IEC 61643-21/A1 2008
Total surge current (10/350) µs (General) 2.5 kA
Ambient temperature (operation) (Dimensions) -40 °C ... 80 °C
Operating effective current ICat UC (General) ≤ 1 µA
Max. discharge current Imax(8/20) µs (General) 20 kA
Nominal discharge current In(8/20) µs (General) 20 kA
Voltage protection level Up(line-earth) (General) ≤ 1.1 kV (C2 - 10 kV / 5 kA)
Total discharge current Itotal(8/20) µs (General) 20 kA
Voltage protection level Up(line-shield) (General) ≤ 900 V (C1 - 1 kV/500 A)
Maximum continuous voltage UC(line-earth) (General) 280 V DC
Standing wave ratio SWR in a 50 Ω system (General) typ. 1.15 (≤ 3 GHz)
Nominal discharge current In(8/20) µs (line-earth) (General) 20 kA
Nominal discharge current In(8/20) µs (line-shield) (General) 20 kA
Nominal pulse current Ian (10/1000) µs (Core-Shield) (General) 100 A
Permissible HF power Pmaxat VSWR = xx (50 ohm system) (General) 700 W (VSWR = 1.1)
Impulse discharge current (10/350) µs, peak value limp (General) 2.5 kA
Output voltage limitation at 1 kV/µs (line-earth) spike (General) ≤ 900 V
Output voltage limitation at 1 kV/µs (line-shield) spike (General) ≤ 900 V
Standards for cearances and creepage distances (Ambient conditions) IEC 60664-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General) 20 kA
Max. discharge current Imax(8/20) µs maximum (line-shield) (General) 20 kA
Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm system (General) > 3 GHz

Product Description

Replaceable surge protection adapter for coaxial signal interfaces. Connection: N Female Connector
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top